Diaphragm Pumps NMP 830, NMP 850 Use
KNF Neuberger BA121556-121559 NMP830_850-EN 0221.doc
Translation of original Operating and Installation Instructions, English, 3
2. Use
2.1. Proper use
The pumps are exclusively intended for transferring gases.
Owner's responsibility
Only install and operate the pumps under the operating parameters
and conditions described in Chapter 4, Technical data.
Only complete pumps may be taken into service.
Make sure that the installation location is dry and the pump is
protected against rain, splash, hose and drip water.
Before using a medium, check whether the medium can be trans-
ferred danger-free in the specific application case.
Before using a medium, check the compatibility of the materials of
the pump head, pump housing, diaphragms, and valves with the
medium.
Only transfer gases which remain stable under the pressures and
temperatures occurring in the pump.
2.2. Improper use
The pumps may not be operated in an explosive atmosphere.
The pumps are not suitable for transferring dusts.
The pumps are not suitable for transferring vapors and liquids.
The pumps must not be used to create vacuum and overpressure
simultaneously.
An overpressure must not be applied to the suction side of the
pump.