Hydraulic ratings
Parameter Value
Flow rate NF 100 [l/min]
1), 2)
1.2
Flow rate NF 1.100 [l/min]
1), 2)
1.3
Flow rate NFB 100 [l/min]
1), 2)
2 x 1.3
Max. permissible pressure NF 100, NFB 100 [bar g] 1
Max. permissible pressure NF 1.100 [bar g] 6
3)
Suction head [mWG] 3
Tab. 6
1)
Measured with water at 20 °C / at atmospheric pressure
2)
Flow rates may vary from the values shown, depending on fluid viscosi-
ty, pump head material and the hoses / hose connectors used.
3)
for DCB and AA version 4 barg
Hydraulic connections
Parameter Value
NF 100 / NF 1.100 / NFB 100 G 1/8"
UNF 100 / UNF 1.100 / UNFB 100 NPT 1/8"
Recommended hose size ID [mm] 8
Tab. 7
Specifications NF 100 AA
Motor voltage 230V / 50Hz
Power consumption [W] 86
Max. I load [A] 0.36
Max. permissible current
consumption [A]
0.50
Protection class [-] IP 54
Weight
1)
[g] 2430
Tab. 8
Specifications NF 100 DC
Motor voltage 12V / 24V
Power consumption [W] 9.6 / 8.4
Max. I load [A] 0.8 / 0.35
Max. permissible current
consumption [A]
2.2 / 1.0
Protection class [-] IP 50
Weight
1)
[g] 600
Tab. 9
Specifications NF 100 DCB
Motor voltage 12V / 24V
Power consumption [W] 11 / 11
Max. I load [A] 0.67 / 0.37
Max. permissible current
consumption [A]
0.93 / 0.46
Protection class [-] IP 30
Weight
1)
[g] 480
Tab. 10