EasyManua.ls Logo

KNF NF 100 - Hydraulic Ratings and Connections

KNF NF 100
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diaphragm liquid pump NF 100 Technical data
KNF Flodos BA_NF100_EN_10_067676.docx
Translation of original Operating and Installation Instructions 8
Hydraulic ratings
Parameter Value
Flow rate NF 100 [l/min]
1), 2)
1.2
Flow rate NF 1.100 [l/min]
1), 2)
1.3
Flow rate NFB 100 [l/min]
1), 2)
2 x 1.3
Max. permissible pressure NF 100, NFB 100 [bar g] 1
Max. permissible pressure NF 1.100 [bar g] 6
3)
Suction head [mWG] 3
Tab. 6
1)
Measured with water at 20 °C / at atmospheric pressure
2)
Flow rates may vary from the values shown, depending on fluid viscosi-
ty, pump head material and the hoses / hose connectors used.
3)
for DCB and AA version 4 barg
Hydraulic connections
Parameter Value
NF 100 / NF 1.100 / NFB 100 G 1/8"
UNF 100 / UNF 1.100 / UNFB 100 NPT 1/8"
Recommended hose size ID [mm] 8
Tab. 7
Specifications NF 100 AA
Motor voltage 230V / 50Hz
Power consumption [W] 86
Max. I load [A] 0.36
Max. permissible current
consumption [A]
0.50
Protection class [-] IP 54
Weight
1)
[g] 2430
Tab. 8
Specifications NF 100 DC
Motor voltage 12V / 24V
Power consumption [W] 9.6 / 8.4
Max. I load [A] 0.8 / 0.35
Max. permissible current
consumption [A]
2.2 / 1.0
Protection class [-] IP 50
Weight
1)
[g] 600
Tab. 9
Specifications NF 100 DCB
Motor voltage 12V / 24V
Power consumption [W] 11 / 11
Max. I load [A] 0.67 / 0.37
Max. permissible current
consumption [A]
0.93 / 0.46
Protection class [-] IP 30
Weight
1)
[g] 480
Tab. 10

Related product manuals