EasyManua.ls Logo

Knox KeySecure 5 - Dual PIN; Light Management; Programming and Updating the KeySecure

Knox KeySecure 5
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1601 W. DEER VALLEY RD. PHOENIX, AZ 85027 | T. 800-552-5669 | TECHSUPPORT@KNOXBOX.COM | KNOXBOX.COM | PAGE 10
OPE-ESYSLR-0325-F
©Knox Company. All rights reserved.
KEYSECURE
®
5 & 6
ADMIN & USER GUIDE
The device does not require a connection to KnoxConnect for a SecurePIN to be generated and used.
The feature can be used in conjunction with normal PIN use. For more information, see the SecurePIN Quick
Start Guide.
Dual PIN
A primary or secondary administrator has the ability to enable the Dual-PIN feature for KeySecure units.
Dual-PIN requires users to enter 2 PINs to release a key on the KeySecure Units. Definitions of PIN features
are below, and the default setting is single PIN.
Single PIN (Independent PIN) Only one PIN is required to release key for KeySecure units
Dual PIN (Dependent PIN) Two PINs of any type are required to release the keys
Supervisor PIN Supervisor PINs are non-dependent and do not require a second PIN.
Also used for changing keypad/display brightness on KeySecure
Light Management
The brightness of a KeySecure’s LEDs and keypad backlight can be adjusted to temporarily reduce
intensity when driving at night or supporting operations requiring no lights. PIN users with Supervisor field
capabilities assigned in KnoxConnect have permission to adjust settings.
Light Modes
Standard: Default setting of keypad backlight and key retention LEDs
Night: Reduces intensity of backlight and LEDs to 50%
Blackout: Turns o all device lights
NOTE: If keys will be used while the unit is in Blackout Mode, Knox recommends removing prior to adjusting
settings as keypad feedback and indicator lights will not be available.
Adjust Light Settings Using Device Keypad:
1. Enter valid Supervisor PIN
2. Press the Knox button. The light mode toggles in the following order:
a. Press once for Night Mode
b. Press twice for Blackout Mode
c. Press three times to return to Standard Mode
TIP: Selection mode will time out after 5 seconds. The device will automatically revert to Standard Mode
after 8 hours.
Programming and Updating the KeySecure
To conduct initial configuration of the KeySecure, you must use the provided USB cable to connect the
KeySecure to a computer.
A SecurePIN can be generated in advance or upon demand. SecurePINs are generated and used for
the specific device selected. It becomes inactive after it is used and will also deactivate any previously
generated SecurePINs generated for that device.