Equipment Overview 7
Table 5: Air and network connections
Other connections
a
Supplied by Kodak Required by customer
b
Network connection
(for connecting to the
workflow)
Ethernet:
100 Base-T (RJ-45)
Network connection and cable
long enough to reach workstation.
3 consecutive IP addresses for the
MCE and RAS connections, plus 1
IP address for the Local Area
Network connection to the
customer network
FDDI: Duplex SC
Drum vacuum pump hose 15.2 m (50 ft.) of 2 in. flexible
vacuum tubing and 4 hose clamps
50.8 mm (2 in.) Schedule 40 PVC
tubing for use where flexible hose
is not required. See Tubing (Pump
to Output Device) on page 18.
Chiller hose 2.5 m (8.2 ft.) long head coolant
hose assembly between the external
chiller and the output device
Workstation interface 7.6 m (25 ft.) long SCSI and serial
interface cables between the
workstation and the output device
Shop air supply (dedicated
branch recommended—see
Air Supply on page 15)
12.7 mm (0.5 in.) national pipe
thread (NPT) female fitting on the
device
A flexible airline, 12.7 mm (0.5 in.)
internal diameter minimum, with
12.7 mm (0.5 in.) male NPT fitting
at the end for connection to the
ThermoFlex Wide II.
The air line must be capable of
delivering 40 SCFM @ 100120 psi.
Keep the airline as short as
possible and free from restrictions.
If the air line is longer than 6.1 m
(20 ft.), use a larger internal
diameter airline.
a. For a diagram of system connections, see Figure 1 on page 8.
b. For the location of the air supply, see Footprint and Working Area on page 9. For further details, see Air
Supply on page 15 and Network on page 20.