6 ThermoFlex Wide II Site Preparation Guide
Table 4: Cables and interconnects—Japan
Cables Supplied by Kodak Supplied by customer
a
Output device main power Attached 4.5 m (14.7 ft.) power cord
with L6-30P plug
Dedicated 30 A, 200 V branch
circuit with slow-blow circuit
breaker and L6-30R receptacle
Drum vacuum drive power Labeled terminals for hookup of AC
mains input cable (3-phase plus
ground). Pilot hole for appropriate
conduit fitting.
Dedicated 20A, 340-506 VAC
(±0%), 50/60 Hz, 3-phase branch
circuit with circuit breaker
protection.
Wiring, circuit breaker and panel
fittings supplied by customer in
accordance with local electrical
standards.
Workstation power 2.5 m (8.2 ft.) power cable with 5-
15P connector
5-15R receptacle and dedicated
100 V, 15 A branch circuit
Chiller power 2.5 m (8.2 ft.) power cable with 5-
15P connector
5-15R receptacle and dedicated
120 V, 15 A branch circuit
Debris removal cabinet power See the UDRC Site Preparation Guide (part number 725-00089A).
Telephone line Serial cable for modem. Two dedicated telephone lines and
RJ-11 cables to plug into modem
(must be long enough to reach
workstation). One line is to
connect to the workflow, and the
other is to connect to Kodak
remote support.
Also requires separate AC power
source (UPS provided only with 5-
15R receptacles).
a. The tolerances for input voltages are +6%, –10%. The specification for the frequency is 50/60 Hz ±1.5%.
Branch circuits should have time delay type circuit breakers to avoid nuisance tripping caused by inrush
currents. For details, refer to Electrical on page 13.