Equipment Overview 5
Table 3: Cables and Interconnects—Europe, Australia and S.E. Asia
Cables Supplied by Kodak Required by customer
a
Output device main power Attached 4.5 m (14.7 ft.) power cord
with L6-30P plug
Dedicated 32A, 200-240 V circuit
with IEC309 32 A/250 V
receptacle and slow-blow circuit
breaker
Drum vacuum drive power Labeled terminals for hookup of AC
mains input cable (3-phase plus
ground). Pilot hole for appropriate
conduit fitting.
Dedicated 20 A, 340-440 VAC
(±0%), 50/60 Hz, 3-phase
branch circuit with circuit breaker
protection.
Wiring, circuit breaker and panel
fittings supplied by customer in
accordance with local electrical
standards.
Workstation power IEC320, type C14 appliance inlet IEC320, type C13 connector with
8A cord
Dedicated 8 A, 200–240 V branch
circuit
Chiller power 2.5 m (8.2 ft.) power cable with 5-
15P connector
Dedicated 120 V, 15 A branch
circuit with 5-15R receptacle
Debris removal cabinet power See the UDRC Site Preparation Guide (part number 725-00089A).
Telephone line Serial cable for modem Two dedicated telephone lines and
RJ-11 cables to plug into modem
(must be long enough to reach
workstation). One line is to
connect to the workflow, and the
other is to connect to Kodak
remote support.
Also requires separate AC power
source (UPS provided only with
IEC type 320 outlet receptacles).
a. The tolerances for input voltages are +6%, –10%. The specification for the frequency is 50/60 Hz ±1.5%.
Branch circuits should have time delay type circuit breakers to avoid nuisance tripping caused by inrush
currents. For details, refer to Electrical on page 13.