Small Karman Vortex Flow Meter
FM01 Series
Instruction Manual
Question and Answer IconNeed help?

Do you have a question about the Kofloc FM01 Series and is the answer not in the manual?

Kofloc FM01 Series Specifications

General IconGeneral
BrandKofloc
ModelFM01 Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

Handling Cautions

Storage Guidelines

Proper storage conditions including temperature, humidity, and protection from elements.

Installation Site Requirements

Key factors for installing the flow meter to ensure safe and accurate operation.

Cautions and Warranty

Usage and Handling Precautions

Precautions against water pressure, freezing, overtightening, and cable strain during handling.

Prohibited Tests

Warning against performing insulation resistance/dielectric strength tests to prevent circuit damage.

Warranty Period and Coverage

Details the warranty duration and conditions for product malfunctions.

Product Introduction

Outline and Measuring Principle

Describes the flow meter's function, Karman vortex principle, and material properties.

Standard Specifications

Technical Specification Summary

Lists key technical parameters including fluid compatibility, material, accuracy, and operating conditions.

Model and Connection Information

Model, Flow Range, and Fittings

Correlates models with their diameter, flow range, and specific connection fittings.

Electrical Connections

Wiring Diagrams and Specifications

Illustrates wiring for current, pulse, and indicator outputs with voltage and load details.

Dimensions and Fittings

Physical Dimensions and Fitting Types

Provides physical dimensions (a, L, X) and fitting types for each FM01 model.

Performance Characteristics

Output vs. Flow Rate Graphs

Visualizes the linear relationship between flow rate (L/min) and output current (mA) for each model.

Alarm Setup

Configuring Alarm Polarity and Thresholds

Step-by-step process for setting alarm polarity and threshold values for AL1 and AL2.

Device Configuration

Flow Unit and Type Settings

Guides on setting flow units (GAL/L) and configuring product types for the meter.

Analog Output Calibration

Instructions for setting the zero and span (4-20mA) for the analog output signal.

Flow Span Calibration

Process for calibrating the flow span based on actual flow device readings.

Detailed Setting Procedures

Setting the Flow Unit

Detailed steps for setting the flow unit to L/min or gal/min.

Setting the Output Zero

Steps to set the zero point for the analog output signal.

Setting the Output Span

Steps to set the span for the analog output signal.

Setting the Flow Span

Procedure for setting the flow span based on actual flow device values.