TP-6735 7/1788 Section 6 Disassembly/Reassembly
6.2 Disassembly
The disassembly procedure explains how to
disassemble the generator set enclosure and other
parts in order to access the alternator for service. The
procedure provides important information to minimize
disassembly time and indicates w here special
configurations exist w hich may require taking notes.
Remove enclosure
Remove the generator set enclosure as described in the
following steps. See Figure 6-1.
1. Open the enclosure roof.
2. Press the OFF button on the controller and remove
fuse F3 (located in the controller’s service access
area). See Figure 4-1.
3. Remove 6 nuts and remove the roof. See
Figure 6-2.
1. Roof
2. Rear panel (exhaust end)
3. Left side panel
4. Front panel (air intake end)
5. Right side panel
1
ADV7341
5
4
3
2
Right Side
Front (air
intake end)
Figure 6-1 Enclosure
GM72523
1. Remove three nuts on each side
1
1
Figure 6-2 Roof Removal