Models:
14RCA
14RCAL
18RCAL
20RCA
20RCAL
Controller:
RDC2
Residential/Commercial Generator Sets
TP-7092 11/22b
Operation

Table of Contents

Other manuals for Kohler 20RCA

Questions and Answers

  • N
    Nicole WardAug 18, 2025
    What to do if the breaker will not close in RUN on my Kohler 20RCA Portable Generator?
    • F
      farleyjudithAug 18, 2025
      If the breaker won't close in RUN on your Kohler Portable Generator, it could be due to: another breaker being closed (stop the other generator set), auto-discovery not being complete (initiate auto-discovery by ensuring this generator is in RUN mode and the other is stopped with the controller in OFF mode), or bus sensing not being connected correctly (check wiring between both generators and the Automatic Paralleling Module).
  • K
    Kelly GarciaAug 28, 2025
    Why does SiteTech indicate that both engines are under load, but the ATS has not transferred on my Kohler 20RCA?
    • J
      jared42Aug 28, 2025
      If SiteTech indicates that both engines are under load but the ATS hasn't transferred on your Kohler Portable Generator, it could be due to the metering on either generator being backwards. To fix this, select a different model number for the affected generator, then re-select the correct model number. This clears the CT direction flag and allows the generators to re-determine CT direction.
  • K
    Kevin LarsonNov 8, 2025
    Why is auto-discovery not completing on my Kohler 20RCA Portable Generator?
    • H
      Heather PetersonNov 9, 2025
      Auto-discovery might not complete on your Kohler Portable Generator due to several reasons: * The device may already be auto-discovered to a different contactor. To resolve this, set the engine model number to a different model and then set it back. This action clears any auto-discover information stored in the controller. * The generator or APM circuit breaker might be tripped. Reset the generator circuit breaker or the circuit breaker in the APM. * There might be bad connections between the generator and APM. Correct these connections. * The generator controller might not be seeing bus voltage. Check the wiring between the generator and the APM, paying special attention to the V9 lead connection, as this is the bus sensing. * The other generator is not in OFF. Press the OFF bu...

Summary

Product Identification Information

Emission Information

Generator Set Application

Service Assistance

Obtaining Professional Service

Provides contact information for nearest dealer and website.

Section 2. Generator Set Operation

Prestart Checklist

Steps to ensure satisfactory operation before starting the generator.

Fault Handling and Resetting

Procedures for identifying, correcting, and resetting faults.

Section 3. RDC2 Controller Operation

Settings and Configuration

Guides on changing controller settings and exerciser parameters.

Section 4. Scheduled Maintenance

Lubrication System Service

Details oil checks, changes, filter replacement, and oil cooler maintenance.

Battery Maintenance and Storage

Provides guidance on battery cleaning, testing, and storage.

Section 5. Troubleshooting

Troubleshooting Introduction

Guides on diagnosing and correcting common generator problems.

Fault Messages and Diagnosis

Lists fault messages and their potential causes and checks.

Safety Precautions and Instructions

General Hazard Classifications

Explains DANGER, WARNING, CAUTION, and NOTICE levels.

Operational Safety

Covers accidental starting, hot parts, and heavy equipment handling.

Electrical and Fire Safety

Addresses hazardous voltage, moving parts, and fire/explosion risks.

Chemical and Environmental Safety

Covers battery acid, carbon monoxide, and noise hazards.

Kohler 20RCA Specifications

General IconGeneral
Rated Output (Watts)20000
Starting MethodElectric
Voltage120/240V
Frequency60 Hz
Fuel TypeGasoline
EngineKohler
Power Output20 kW
Dimensions48.5 in x 29.5 in x 39 in

Related product manuals