What to do if there is air in the fuel system of my Kohler 32EKOZD Portable Generator?
- CCurtis BlackSep 1, 2025
If there is air in the fuel system of your Kohler Portable Generator, bleed the diesel fuel system. The cause is air in the fuel system.
What to do if there is air in the fuel system of my Kohler 32EKOZD Portable Generator?
If there is air in the fuel system of your Kohler Portable Generator, bleed the diesel fuel system. The cause is air in the fuel system.
What to do if my Kohler 32EKOZD Portable Generator breaker is not charged?
Verify that the motor operator is receiving voltage at the appropriate contacts, allowing it to wind the spring.
How to fix a faulty ground connection on my Kohler 32EKOZD Portable Generator?
If you find a faulty ground connection in your Kohler Portable Generator, clean and retighten the connection. The cause is a faulty ground connection.
How to fix CB trip relay wired as normally open in Kohler 32EKOZD?
Check that the CB trip relay is wired to hold a trip on the breaker when the relay is not energized.
How to fix intermittent connection in PGEN wiring in Kohler 32EKOZD Portable Generator?
Confirm that there are no loose wiring connections or “whiskers” at the PGEN terminal blocks. Using “Fork”, “ring”, or “crow’s feet” connectors for terminal block connections is preferable.
How to resolve breaker status feedback is not valid, no bus sensing in Kohler 32EKOZD?
Verify the wiring on the circuit breaker to ensure it is connected correctly. Verify bus wiring for all nodes. Verify the generator output is connected to the line side of the generator breaker.
What to do if my Kohler Portable Generator shuts down due to low oil pressure?
If your Kohler Portable Generator experiences a low oil pressure shutdown, check the oil level. This is due to low oil pressure shutdown.
What to do if my Kohler Portable Generator is experiencing an engine overload?
If your Kohler Portable Generator experiences an engine overload, reduce the electrical load. The cause is engine overload.
How to fix loose or corroded battery connections on a Kohler Portable Generator?
If the battery connections of your Kohler Portable Generator are loose, corroded, or incorrect, verify that the battery connections are correct, clean, and tight. The cause of this problem is that the battery connections are loose, corroded, or incorrect.
What to do if my Kohler Portable Generator runs out of fuel or the fuel valve is off?
If your Kohler Portable Generator's fuel tank is empty or the fuel valve is shut off, add fuel and move the fuel valve to the ON position. This is because the fuel tank is either empty, or the fuel valve is shut off.
Model | 32EKOZD |
---|---|
Type | Portable Generator |
Voltage | 120/240V |
Frequency | 60 Hz |
Warranty | 3 years limited |
Maximum AC Output | 32000 watts |
Steps to perform before starting the generator set, covering air inlets, battery, coolant, and exhaust.
Covers controller modes (OFF, RUN, AUTO), start/stop signals, and engine cooldown.
Details accessing controller data via display or PC using SiteTech™ software.
Provides a detailed service schedule for specific generator models, including intervals and tasks.
Provides a detailed service schedule for specific generator models, including intervals and tasks.
Details oil specifications, oil checks, and oil change procedures.
Covers fuel specifications, fuel filter replacement, and fuel system bleeding.
Chart to diagnose and resolve issues related to controller display and voltage regulation.
Critical safety warning about accidental starting and procedures to prevent it.
Dangers associated with electrical voltage and moving parts requiring safety measures.