TP-6390 1/0620 Section 2 Operation
Code Fault Description Check
CO-4 Carbon monoxide
warning
Fault code is displayed if the presence of CO is
detected because of the time-weighted average
presence of CO. Activates the CO cabin alarms.
Ensure windows are open for proper ventilation.
Operate the blower to expel dangerous fumes.
Move the vessel away from other vessels (as another
vessel may be the source for the presence of the CO).
Check the generator exhaust system (see Section 3.6).
Contact an authorized distributor/dealer for service if
problem continues.
CO-5 Carbon monoxide
warning
Fault code is displayed if the presence of CO is
detected. Warning occurs if the sensor detects
acceptable but increasing CO levels.
Ensure windows are open for ventilation.
Operate the blower to expel dangerous fumes.
Move the vessel away from other vessels (as another
vessel may be the source for the presence of the CO).
Check the generator exhaust system (see Section 3.6).
Generator service for emissions required.
Contact an authorized distributor/dealer for service if
problem continues.
CO-6 Carbon monoxide
sensor warning
Fault code is displayed if the CO sensor is inoperative. Replace the CO sensor.
Contact an authorized distributor/dealer for service if
problem continues.
HB High battery
voltage warning
Fault code is displayed if the engine starting battery
voltage rises above 16 VDC for a 12 VDC system or
above 30 VDC for a 24 VDC system for more than
2 seconds when the engine is not running. This fault
condition does not inhibit engine starting.
The fault condition clears when the battery voltage
returns to a voltage within the limits for more than
2 seconds.
Check the battery rating and condition.
LB Low battery
voltage warning
Fault code is displayed if the engine starting battery
voltage falls below 9.5 VDC for a 12 VDC system or
below 16 VDC for a 24 VDC system for more than
2 seconds when the engine is not running. This fault
condition does not inhibit engine starting.
The fault condition clears when the battery voltage
returns to a voltage within the limits for more than
2 seconds.
Check the battery rating and condition.
Charge or replace the battery.
Figure 2-6 ADC 2100 Fault Warning Codes

Other manuals for Kohler 4EFCD-Low CO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 4EFCD-Low CO and is the answer not in the manual?

Kohler 4EFCD-Low CO Specifications

General IconGeneral
BrandKohler
Model4EFCD-Low CO
CategoryMarine Equipment
LanguageEnglish

Related product manuals