TP-6137 5/03 11Section 3 Scheduled Maintenance
Perform Service at Intervals
Indicated (X)
Daily
Every
50 Hrs.
or 1
Month
Every
100 Hrs.
or 3
Months
Every
200 Hrs.
or 6
Months
Every
400 Hrs.
or 12
Months
Every
600 Hrs.
or 18
Months
INTAKE/EXHAUST SYSTEM
Inspect the exhaust system components *
X
(Before
operation)
Check the exhaust gas condition. If the exhaust is blue or
black, contact your local distributor/dealer
X
(During
operation)
Clean the intake silencer element * X
Clean the exhaust/water mixing elbow *[
X
Replace the intake silencer element * X
Inspect the complete exhaust system k X
ELECTRICAL SYSTEM
Keep the battery charged and in good condition w
X
(Before
operation)
Check and tighten the electrical connections * X
Clean the battery cables [
X
ENGINE AND MOUNTING
Check for water, fuel, and oil leakage *[]
X
(After
operation)
Retighten any loose nuts and bolts *
X
(Before
operation)
X
Check the mounting bolts/vibromounts and tighten if
necessary *
X
Adjust the intake/exhaust valve clearance *[ X
Head bolt retightening *[ X
REMOTE CONTROL SYSTEM
Check the remote control operation
X
(Break-in
period)
X
GENERATOR
Test run the generator set
X
(Weekly)
Blow dust out of the generator *[
X
* Requires removal of the sound shield, if installed
[ Consult your local distributor/dealer for service
] Read the WARNING found at the beginning of the manual
w Consult the operating instructions supplied with the craft
k Should be performed by your local distributor/dealer