EasyManua.ls Logo

Kohler 6EKOD - Introduction; Service Assistance

Kohler 6EKOD
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TT-1715 2/17 11
Digital
Gauge
Display
ADC II
Display
Description
59
WARN
ECT input lo Warning: Coolant Sensor Input Low
60
ERR
Fault O2 input hi Shutdown: Oxygen Sensor Input High
61
ERR
Fault O2 input lo Shutdown: Oxygen Sensor Input Low
62
ERR
Fault Coolant loss Shutdown: Sea Pump Pressure
64
ERR
Fault Over speed Shutdown: Engine Overspeed
65
ERR
Fault Hi eng temp Shutdown: Coolant Sensor Range High
65
WARN
Hi eng temp Warning: Coolant Sensor Range High
69
ERR
Fault O2 limit err Shutdown: O2 Switching Fault
70
ERR
Fault O2 adapt Shutdown: Gaseous O2 Adapt Limit Fault
74
ERR
Fault Starter Shutdown: Starter Fault
75
WARN
O2 sens open Warning: Oxygen Sensor Open-Circuit
100
WARN
Oil sens err Warning: Oil Pressure Input High
101
WARN
Oil sens err Warning: Oil Pressure input Low
Hb
WARN
High battery Warning: High Battery Voltage
Lb
WARN [
Low Battery or
Weak battery
Warning: Low Battery Voltage
OC
ERR [
Fault Over crank or
Fault Locked rotor
Shutdown: Over Crank
LOC
ERR
Fault Coolant loss Shutdown: Loss of Coolant
AF
ERR [
Fault Auxiliary
Fault Hi exh temp
Fault ECM voltage
Fault HVR Comm Err
Shutdown: Auxiliary Fault Input
Shutdown: High Exhaust Gas Temp
Shutdown: Battery Too Low
Shutdown: Communication Loss
OU
ERR
Fault Over voltage Shutdown: Over Voltage
UU
ERR
Fault Under volt Shutdown: Under Voltage
OF
ERR
Fault Over freq Shutdown: Over Frequency
UF
ERR [
Fault Under freq Shutdown: Under Frequency
EC61
ERR
Fault CAN loss Shutdown: Loss of CAN Communications
CO-1
ERR
Fault Hi CO:sensor Shutdown: CO Detected (shutdown level)
CO-3
ERR
Fault No CO sensor Shutdown: Loss of CO Sensor Heartbeat
CO-6
WARN
CO sensr err Warning: CO Sensor Defect
CO-5
WARN
Hi CO: sensor Warning: CO Detected (warning level)