Marine Generator Sets
Models:
6EKOD
9--11EKOZD
5EFKOD
7--9EFKOZD
TP-6772 2/14b
Operation

Table of Contents

Other manuals for Kohler 5EFKOD

Questions and Answers

  • B
    Bobby ZhangSep 9, 2025
    What to do if my Kohler Inverter experiences a high temperature shutdown?
    • T
      Tracey NashSep 9, 2025
      If your Kohler Inverter shows a high temperature shutdown, allow the engine to cool down completely. After it cools down, troubleshoot the cooling system to identify the root cause.
  • J
    John FieldsSep 15, 2025
    What to do if the controller fuse (F2) is blown in Kohler Inverter?
    • M
      Matthew SanchezSep 16, 2025
      If the controller fuse (F2) is blown in your Kohler Inverter, replace the blown fuse. If the fuse blows again, troubleshoot the controller.
  • M
    Melissa SimmonsSep 3, 2025
    What causes high oil use in my Kohler 5EFKOD Marine Equipment?
    • B
      Brian MooreSep 3, 2025
      If your Kohler Marine Equipment generator has high oil use, replace the gaskets to address external leakage or defective gaskets. Also check compression, as the issue might be worn piston rings or valves.
  • F
    Frank JonesAug 26, 2025
    What to do if my Kohler Marine Equipment generator set does not crank?
    • K
      Krista SimmonsAug 27, 2025
      If your Kohler Marine Equipment generator set does not crank, there are several potential causes. It could be due to a weak or dead battery, in which case you should recharge or replace the battery. Check for reversed or poor battery connections. Inspect for loose connections or open circuits in the engine/controller connections, and verify the wire harness continuity. Replace the F2 fuse if it's blown; if it blows again, inspect the circuit and components, controller wiring, starter solenoid, and wiring for open grounds, loose connections, or pushed-out pins. Check the crank relay for 12VDC on lead 71N. Clean and retighten any poor ground connections. Inspect the starter and controller connections and operation, ensuring power to the controller.
  • K
    Kenneth HahnAug 27, 2025
    Why my Kohler Marine Equipment cranks but does not start?
    • D
      davidpayneAug 27, 2025
      If your Kohler Marine Equipment generator cranks but does not start, begin by checking the fuel supply and fuel filters for any blockages. Inspect for loose or open connections at the fuel pump or fuel solenoid, and check the controller/engine wiring continuity. Ensure that the controller configuration settings are correct. Also, check for a locked rotor, which may be indicated by an overcrank fault shutdown.
  • S
    Steve JohnsonAug 27, 2025
    What to do if my Kohler 5EFKOD Marine Equipment starts but shuts down?
    • C
      Charles TorresAug 27, 2025
      If your Kohler Marine Equipment generator starts but shuts down, check the controller’s display for a fault shutdown code. Correct the fault and then reset the controller.
  • B
    Brendan TuckerSep 16, 2025
    What to do if the customer connection fuse (F3) is blown in Kohler Inverter?
    • G
      Gregory WarnerSep 17, 2025
      If the customer connection fuse (F3) is blown in your Kohler Inverter, replace the blown fuse. If the fuse blows again, check what is connected to the generator set.
  • T
    timothywestNov 27, 2025
    Why does my Kohler Marine Equipment generator stop suddenly?
    • M
      Melissa MorseNov 27, 2025
      If your Kohler Marine Equipment generator stops suddenly, check the controller’s display for a fault shutdown code and correct the fault, then reset the controller. Also, check the fuel supply, fuel lines, and fuel filter for any blockages. Replace the controller fuse (F2) and check the wiring to the controller. Replace the auxiliary winding fuse (F1); if it blows again, test the generator components. If the engine is hot, check the air intake, fuel, oil level, and air inlet/outlet. For low oil pressure, attempt startup; if the unit shuts down and displays 'Oil Pres Low Shutdwn', remove the lead from the LOP sender and reset the controller. A successful restart indicates a faulty LOP shutdown sender. Reduce the electrical load if the engine is overloaded. Check connections at the P2 plug a...
  • T
    Tina WhitakerSep 10, 2025
    What to do if Kohler Inverter shows overspeed shutdown?
    • B
      butlermonicaSep 10, 2025
      If your Kohler Inverter displays an overspeed shutdown, begin by resetting the controller. However, if the overspeed fault happens again, it's recommended to contact your distributor or dealer for further assistance.
  • R
    Richard HillSep 4, 2025
    Why does my Kohler 5EFKOD generator have high output voltage?
    • N
      Nicole SalazarSep 4, 2025
      If your Kohler Marine Equipment generator has high output voltage, check and adjust the controller configuration settings and voltage settings. Verify the engine speed using a tachometer or frequency meter and adjust the governor as necessary. Check connections at the stator leads 11 and 44 (for 1-phase models) or leads V7, V8, and V9 (for 3-phase models) and the P2 controller connection to address loose voltage sensing connections.

Summary

Product Identification Information

Generator Set Identification Numbers

Record for identifying the generator set model and serial number for service.

Engine Identification

Record for identifying the engine model and serial number for service.

Safety Precautions and Instructions

Accidental Starting

Critical safety procedures to prevent accidental generator set startup during maintenance.

Fire and Flammability Hazards

Warnings about flammable fuels, sparks, and fire risks during operation and maintenance.

Exhaust System Safety and Warnings

Safety information regarding the exhaust system, emphasizing carbon monoxide risks.

Carbon Monoxide Exposure Risks

Detailed information on the dangers and symptoms of carbon monoxide exposure from exhaust gases.

Safe Fuel System Handling

Precautions for safely handling, storing, and using fuels to prevent leaks and explosions.

Noise Exposure Hazards

Warning about potential hearing loss from generator set noise and the need for a muffler.

Electrical and Mechanical Hazards

Critical safety warnings about electrical shock and injury from moving components and wiring.

Electrical System Safety

Warnings about short circuits, backfeed, and testing live electrical circuits to prevent injury.

Hot Component Safety

Safety advice concerning hot components like coolant and steam, and precautions before servicing.

General Safety Notices

Notices regarding fuse replacement, saltwater damage, and general maintenance safety.

Introduction

Service Assistance

Maintenance and Service Parts;Related Literature

Maintenance and Service Parts

List of recommended parts for maintenance and service of the generator set.

List of Related Literature

References to other manuals and documentation for generator set installation, operation, and service.

Section 1 Service Views

Typical Service Views Diagram

Illustrated diagrams showing the typical components and service points of the generator set.

Section 2 Operation

2.1 Prestart Checklist

Essential checks to perform before starting the generator set for safe and satisfactory operation.

Marine Operation and Inspection

Recommendations for boat inspections, angular limits, EU operation, and load profile guidelines.

Advanced Digital Control Operation

Detailed guide on operating the generator set using the Advanced Digital Control interface and its features.

Controller Logic Specifications

Information on controller settings, time delays for faults, and warning specifications for generator set operation.

Menu Display Navigation

Summary of available menu displays for monitoring generator set data and settings.

Controller Monitoring and Setup

Procedures for accessing and setting up controller data via the digital display or a personal computer.

Menu Display Data Review

Guide to navigating and understanding various data points and adjustments available through the controller menus.

Section 3 Scheduled Maintenance

3.1 General Maintenance

Basic maintenance tasks, safety precautions, and general service guidelines for the generator set.

3.2 Service Schedule

Detailed schedule of maintenance tasks and their required intervals for specific generator set models.

Lubrication System Maintenance

Procedures and specifications for checking and changing engine oil and oil filters.

Fuel System Maintenance

Guidelines for fuel specifications, replacing the fuel filter, and bleeding the fuel system.

Exhaust System Maintenance

Instructions for inspecting and maintaining the exhaust system to ensure safety and performance.

Cooling System Maintenance

Procedures for checking, filling, flushing, and cleaning the engine cooling system and its components.

Belt Tension Adjustment

Instructions for checking and adjusting the seawater pump belt tension for proper operation.

Battery and Storage Procedures

Guidelines for battery care, maintenance, and proper procedures for storing the generator set.

Section 4 Troubleshooting

Fault Code Diagnostics

Information on fault codes displayed by the controller and diagnostic procedures for identifying issues.

Troubleshooting Guide

Tables listing common trouble symptoms, probable causes, and recommended actions for diagnosing and fixing problems.

Section 5 Wiring Diagrams

Wiring Diagram Overview

A guide to referencing point-to-point and schematic wiring diagrams for different generator set models.

Wiring Diagrams: Non-Isolated Ground

Schematic and point-to-point wiring diagrams for generator sets without an isolated ground configuration.

Wiring Diagrams: Isolated Ground

Schematic and point-to-point wiring diagrams for generator sets with an isolated ground configuration.

Kohler 5EFKOD Specifications

General IconGeneral
BrandKohler
Model5EFKOD
CategoryMarine Equipment
LanguageEnglish