Operating fluids and maintenance Operation and Maintenance Manual
Maintenance
5.3.2 Daily, weekly and monthly maintenance work
SL000 Diesel engine
Daily X
Perform visual inspection (leaks, damage, loose
components). Perform before start.
SL001 Engine oil and
coolant
Daily X
Check engine oil and coolant level. Refill if necessary.
Perform before start.
SL002 Cooling system
Daily X
Inspect low temperature circuit, intercooler, water pump
and vent line. Perform before start.
SL004 Fuel system
Daily X
Check water trap on the preliminary fuel filter and drain
water if necessary. Perform before start.
SL006 Air filter
Daily X
Check the air filter's display. Perform before start. See the
generator set’s operating manual.
SL007 Engine in
operation
Daily X
Observe the engine operation. Record and report any
abnormality found (faulty parameters, unusual noises,
vibrations, exhaust gas color). See the generator set’s
operating manual.
Diesel engine
Weekly X
Perform visual inspection (leaks, contamination, damage,
belt drive, cable harness)
SL008
Monthly X
Test run at more than 1/3 load. See the generator set’s
operating manual.
Tab. 17: Maintenance schedule — Daily maintenance activities — Service level 1
46
© 2017 by Kohler Co. All rights reserved.
KD27V12 33521029401_3_1 en 2017-07-01