TT-1625 7/17c
INSTALLATION INSTRUCTIONS
Original Issue Date: 3/14
Model:
Generator Sets with APM802 Controller; Decision-Makerr 3+, 550, 3000,
3500, 6000, and 8000 Controllers; and KPC 1000 Controller
Transfer Switches with Decision-Makerr MPAC 750, 1000, 1200, and 1500
Controllers
Market: Industrial
Subject: Remote Serial Annunciator (RSA III) Kits (Firmware Version 1.0)
Introduction
RSA III is an annunciator panel offered in several kit
configurations to support Kohler power equipment. The
RSA III is a remote serial annunciator (Figure 1,
Figure 2, and Figure 3) that monitors the condition of
the generator set and/or ATS from a remote location.
The RSA III alerts the operator through visual and
audible signals using LED indication and a horn. An
alarm silence and lamp test switch are included.
The RSA III meets NFPA 110, Level 1 applications that
require remote controls and alarms be powered by a
storage battery such as the engine starting battery. AC
adaptor kit GM62466-KP1 is available when NFPA is
not required.
The front panel decals include areas that can be used to
identify user-selected fault inputs and identify
associated power system equipment.
Figure 1 Remote Serial Annunciator (RSA III)
An RSA III annunciator can be used for a single
generator set (Figure 1) or with a combination of a
generator set and automatic transfer switch(es)
(Figure 2 or Figure 3). In systems using more than a
single RSA III, one must be designated as the master
device to broadcast to additional RSA III annunciators,
designated as slave devices. Up to five RSA III slave
devices can be used with an RSA III master device. All
RSA III annunciators are factory set as the master
device, but can be changed to a slave device using a PC
and SiteTecht software that connects to the RSA III
front panel via a universal serial bus (USB) connection.
The RSA II can be connected with the RSA III provided
that the master remote annunciator is an RSA III.
Figure 2 RSA III with Single ATS Control
Figure 3 RSA III with Four ATS Controls

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kohler KPC 1000 and is the answer not in the manual?

Kohler KPC 1000 Specifications

General IconGeneral
BrandKohler
ModelKPC 1000
CategoryController
LanguageEnglish

Summary

Installation Instructions

RSA III Features

Horn, Alarm, and Switch Functions

Details on RSA III horn, external horn contacts, and switch functions like alarm silence and lamp test.

Communications and LED Indicators

System Monitoring LEDs

Explanation of various LED indicators for system status, warnings, and faults.

Faults, Status, and Configuration

Detailed Fault Explanations

Detailed explanations of various fault and status conditions indicated by LEDs and the system.

User Inputs, Mounting, and Safety

Safety Precautions for Installation

Critical safety warnings and procedures to prevent accidental starting and ensure safe handling.

Installation Procedures

Controller Configuration and SiteTech Setup

Controller Configuration Steps

Steps to configure various Kohler controllers (DEC 3+, APM802, DEC 550/6000, DEC 3000/3500, DEC 8000) for RSA III communication.

SiteTech Software Setup

Instructions for using SiteTech software to configure the RSA III master and slaves.

User-Defined Settings Configuration

Table detailing display, default, range, and configuration options for RSA III settings.