EasyManua.ls Logo

Kohler APM802 User Manual

Kohler APM802
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TT-1625 7/17c
INSTALLATION INSTRUCTIONS
Original Issue Date: 3/14
Model:
Generator Sets with APM802 Controller; Decision-Makerr 3+, 550, 3000,
3500, 6000, and 8000 Controllers; and KPC 1000 Controller
Transfer Switches with Decision-Makerr MPAC 750, 1000, 1200, and 1500
Controllers
Market: Industrial
Subject: Remote Serial Annunciator (RSA III) Kits (Firmware Version 1.0)
Introduction
RSA III is an annunciator panel offered in several kit
configurations to support Kohler power equipment. The
RSA III is a remote serial annunciator (Figure 1,
Figure 2, and Figure 3) that monitors the condition of
the generator set and/or ATS from a remote location.
The RSA III alerts the operator through visual and
audible signals using LED indication and a horn. An
alarm silence and lamp test switch are included.
The RSA III meets NFPA 110, Level 1 applications that
require remote controls and alarms be powered by a
storage battery such as the engine starting battery. AC
adaptor kit GM62466-KP1 is available when NFPA is
not required.
The front panel decals include areas that can be used to
identify user-selected fault inputs and identify
associated power system equipment.
Figure 1 Remote Serial Annunciator (RSA III)
An RSA III annunciator can be used for a single
generator set (Figure 1) or with a combination of a
generator set and automatic transfer switch(es)
(Figure 2 or Figure 3). In systems using more than a
single RSA III, one must be designated as the master
device to broadcast to additional RSA III annunciators,
designated as slave devices. Up to five RSA III slave
devices can be used with an RSA III master device. All
RSA III annunciators are factory set as the master
device, but can be changed to a slave device using a PC
and SiteTecht software that connects to the RSA III
front panel via a universal serial bus (USB) connection.
The RSA II can be connected with the RSA III provided
that the master remote annunciator is an RSA III.
Figure 2 RSA III with Single ATS Control
Figure 3 RSA III with Four ATS Controls

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kohler APM802 and is the answer not in the manual?

Kohler APM802 Specifications

General IconGeneral
ModelAPM802
Power Supply24 VDC
Housing MaterialPlastic
Communication ProtocolModbus RTU
Input Voltage24 VDC
Operating Temperature-20°C to 60°C
Storage Temperature-40°C to 85°C

Summary

Introduction to the RSA III

RSA III Overview and Functionality

Details the RSA III panel's role in monitoring generator sets and ATS, providing alerts, and its NFPA compliance.

RSA III Features and Indicators

Audible Alarms and Horn Operation

Explains the alarm horn functionality, sound level variations, and external horn contact options.

Front Panel Controls and Switches

Describes the functions of the Alarm Silence, Lamp Test, and Keyswitch on the RSA III unit.

LED Indicators for System Status

Details the purpose and behavior of various LEDs, including specific fault and status indicators.

Common Faults, Communication, and System Status

Managing Common Faults and Communication Status

Covers common fault configuration, communication status LEDs, and troubleshooting tips.

System Monitoring Indicators Explained

Explains all system status indicators for generator set, engine, and system faults.

Installation and Configuration

User Defined Inputs Configuration

Details how to use and configure user-defined digital inputs for monitoring various system events.

Mounting Procedures for RSA III

Provides instructions for surface and flush mounting the RSA III unit.

Critical Safety Precautions

Outlines essential safety measures to prevent accidental starting and ensure safe installation.

Detailed Installation Procedure

Controller Preparation and Wiring

Covers removing the generator set from service, preparing DEC 3+ controller boards, and mounting communication modules.

Mounting the RSA III Unit

Provides detailed steps for surface and flush mounting the RSA III, including box preparation.

Wiring the RSA III

Wiring Guidelines and Specifications

Outlines general wiring guidelines, cable specifications, and notes for RS-485 communication.

Connector Pin Assignments and Wiring

Details wiring for specific RSA III connectors like P27, P34, P37, P39, P40, P41, and P42.

Controller-Specific Wiring Details

Explains RS-485 connections for APM802, DEC 3+, DEC 3000, DEC 3500, DEC 550, and DEC 6000 controllers.

RS-485 Network Configuration

DEC 8000 Controller RS-485 Wiring

Details RS-485 connections and termination for the DEC 8000 controller.

Master/Slave RSA III RS-485 Setup

Explains how to configure RSA III units as masters or slaves using RS-485 connections and termination resistors.

Power and Other Connections

P37 Power and CAN Connections

Details the 3-pin power connections for the RSA III, including battery and AC adapter kit.

P39 Isolation Jumper and P40 Dry Contacts

Explains the P39 isolation jumper settings and P40 dry contact relay outputs for fault and horn signals.

User Input Connections

P41 and P42 Input Wiring

Details wiring for P41 (EPS/User Inputs 1-3) and P42 (User Inputs 4-5) connectors.

Controller-Specific Digital Input Mapping

Explains how digital inputs map to RSA III user inputs for APM802, DEC 550/6000, and DEC 8000 controllers.

Final RSA III Installation

Completing Surface Mount Installation

Details the final steps for surface mounting the RSA III, including positioning and securing the unit.

Completing Flush Mount Installation

Details the final steps for flush mounting the RSA III, including wall plate alignment and securing the unit.

Controller Configuration

DEC 3+ Controller Setup

Details how to configure the DEC 3+ controller for the remote serial annunciator using DIP switches and module installation.

APM802 Controller Setup

Explains the default settings for APM802 controllers to work with the RSA III and address matching.

DEC 550/6000 Controller Configuration

Guides through configuring DEC 550 and DEC 6000 controllers for the remote serial annunciator via menus.

DEC 3000/3500 and DEC 8000 Controller Setup

Covers configuration for DEC 3000/3500 (Modbus address) and DEC 8000 (RS-485 settings).

SiteTech Software Configuration

Using SiteTech Software for RSA III Setup

Describes the process of using SiteTech software to configure RSA III master and slave devices.

SiteTech Software Menu and Settings Overview

Explains the SiteTech software fields and provides an overview of configurable settings and ranges.

Understanding SiteTech Software Fields

Details the Identity, Modbus, Product Connections, and Product Connection Inputs fields within SiteTech.

Configuring Product Connections in SiteTech

Explains how to configure product connections, including EPS, ATS, and generator set inputs within SiteTech.

Wiring Diagrams and Interconnections

RSA III Controller Wiring Diagrams

Provides detailed wiring diagrams for various controllers (DEC 3+, 3000, 3500, 550, 6000, APM802) connected to RSA III.

Network and Interconnection Diagrams

Illustrates interconnection diagrams for RSA III with ATS, networks, and power sources.

Parts List

Remote Serial Annunciator Kits

Lists components included in various Remote Serial Annunciator kits (GM91356 series).

Associated Kits and Components

Lists components for Communication Module Kit (GM32644-KP1) and AC Adapter Kit (GM62466-KP1).

Related product manuals