5
1232447-W2-A
Operating Temperature 0°C - 60°C
Maximum Relative Humidity 100% condensing
USB Cable Length 1 m
Output Power 1.5 Watts into 4 Ohms
Total Harmonic Distortion <1% at 1 kHz full output power
BLUETOOTH
®
wireless range 10 m
Battery Charge Time 7 hours
Play Time* 7 hours
Charge Voltage USB 5 V
*Actual battery life will vary with use,settings and environmental conditions. Rechargeable batteries
have a limited number of charge cycles.
Recommended Hot Supply 0°C to 65°C (Note! The mixing valve can operate at
temperatures up to 85°C for short periods without damage.
However for safety reasons it is recommended that the
maximum hot water temperature is limited to 65°C).
Minimum Recommended Differential
between Hot Supply and Outlet
Temperature
12°C at desired ow rates.
Minimum hot water supply temperature 55°C.
Wireless Speaker Specication
INSTALLATION
Gravity Fed:
The thermostatic mixer must be fed from a cold water cistern (usually tted in the loft space) and
a hot water cylinder (usually tted in the airing cupboard) providing nominally equal pressures.
Gas Heated System:
The thermostatic mixer can be installed with a combination boiler.
Unvented Mains Pressure System:
The thermostatic mixer can be installed with an unvented, stored hot water system.
Mains Pressurised Instantaneous Hot Water System:
The thermostatic mixer can be installed with systems of this type with balanced pressures.
Pumped System:
The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump must
be installed on the oor next to the hot water cylinder.
Suitable Plumbing Systems