113341-2-BB
2000 Kohler Co.
REVIVAL
DECK-/BATH-MOUNT BATH FAUCET
1. BEFORE YOU BEGIN
HOW TO USE THESE INSTRUCTIONS
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will aid you in avoiding the
unnecessary expense associated with improper
installation. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based on the latest
product information available at the time of publication.
Kohler Co. reserves the right to make changes in product
characteristics, packaging, or availability at any time
without notice.
MODEL NUMBERS
K-T16119
K-T16122
K-T16124
K-T16119M
K-T16122M
K-T16124M
PRODUCT REQUIREMENTS
Deep rough-in kit #73444 allows an additional 1/2”
(1.3cm) of tile thickness.
Plaster guard diameters are approximately 1-5/8”
(4.1cm) for the valve and 7/8” (2.2cm) for the spout.
Installer-supplied copper tubing to be: 5/8” O.D.
(1/2” nominal).
Install water hammer arrestors in supply lines near
the valves.
TOOLS AND MATERIALS REQUIRED
Open end/adjustable wrenches
Adjustable arc pliers
1/2” Nom. (5.8” O.D.) tubing
Tubing Cutter
Hole cutting equipment
Soldering equipment and supplies
Phillips screwdriver
INSTALLER INFORMATION
These instructions cover two methods of
installation: installation on finished deck or bath
rim, and installation on rough (unfinished) deck (to
be covered later with tile or other finish material).
Leave protective sleeve on spout supply tube until
spout installation. This is an O-Ring sealing surface
which may be damaged when unprotected.
Finish deck material must fit closely to the
diameters of the plaster guards, especially the
spout plaster guard.
Provide an access panel to valves from underside
of deck.
2-5/8” (6.7cm) D.
2-5/8” (6.7cm) D.
4-3/8”
(11.1cm)
1-1/8”
(2.9cm)
1-3/4”
(4.4cm)
4-3/4”
(12.1cm)
6-1/4” (15.9cm)
(scroll knob)
6” (15.2cm)
(traditional knob)
9-5/8” (24.4cm)
1-5/8” (4.1cm)
6-5/8” (16.8cm)
1-5/8” (4.1cm)
DECK-MOUNT
BATH-MOUNT
6-1/4” (15.9cm)
(scroll knob)
6” (15.2cm)
(traditional knob)
DOME
3” (7.6cm)
1” (2.5cm)
3” (7.6cm)
2-1/2” (6.4cm) D.
4-1/4”
(10.8cm)
1-1/4”
(3.2cm)
2-1/2” (6.4cm)
1” (2.5cm)
TRADITIONAL
4-1/4”
(10.8cm)
2-1/2” (6.4cm) D.
3” (7.6cm)
1” (2.5cm)
3”
(7.6cm)
LEVER
2-1/2” (6.4cm) D.
ROUGHING-IN DIMENSIONS – SPOUT AND HANDLES
Fig. #1
Question and Answer IconNeed help?

Do you have a question about the Kohler REVIVAL Series and is the answer not in the manual?

Kohler REVIVAL Series Specifications

General IconGeneral
StyleTraditional
Handle StyleLever
Valve TypeCeramic Disc
SeriesRevival
ADA CompliantYes
WarrantyLifetime Limited Warranty
Number of Handles2
Faucet Centers8 inches
Flow Rate1.2 GPM
FinishPolished Chrome
Installation TypeWidespread

Summary

Before You Begin

How to Use These Instructions

Read these instructions carefully to familiarize yourself with required tools, materials, and installation sequences.

Product Requirements

Details necessary components and materials, such as rough-in kits, tubing sizes, and water hammer arrestors.

Tools and Materials Required

Lists all necessary tools and materials for the installation process, including wrenches and soldering equipment.

Installer Information

Provides notes for installers on installation methods, spout sleeve usage, and deck material fit.

Roughing-In Dimensions

Illustrates critical dimensions for spout and handle rough-in installations for deck and bath mounts.

Installation

Preparation and Spout Supply Tube

Prepares by cutting tubing, then installs the spout supply tube, securing it with a washer and nut.

Install Valve Bodies

Installs valve bodies with mounting hardware, orienting the cold valve correctly and connecting tubing.

Set Valve Body Height (Rough Deck)

Calculates and sets valve body height for finish material clearance on rough decks.

Supply Tube Connection (Rough Deck)

Connects supply tube to tee and cuts copper tubing to size for rough deck installations.

Rough Deck Assembly Steps

Adjusts collars, pivots valve bodies, and connects tubing for rough deck installations.

Reset Valve Body Height (Rough Deck)

Adjusts threaded collars to match calculated clearance for rough deck installations.

Final Connections (Rough Deck)

Secures valve bodies and solders copper tubes for rough deck installations.

Installation Checkout

Leak Testing and Preparation

Tests for leaks, relieves pressure, and installs plaster guards before spout installation.

Install Tile (If Applicable)

Tile Installation Verification

Verifies clearance between sleeve and tile for proper valve installation before tiling.

Install Spout

Spout Installation Procedure

Removes pipe plug, cuts spout supply tube, and installs spout with plumbers putty.

Sleeve Installation for Tile

Installs sleeve on spout supply tube with brass washer for tiled rough decks.

Spout Assembly and Sealing

Installs spout onto sleeve using plumbers putty, ensuring proper sealing.

Install Handles

Handle Preparation

Removes guards and sleeves, and presses stem extension onto valve stem.

Handle Alignment and Attachment

Applies putty, attaches handle/skirt, and aligns handles for proper fit and function.