Vers. 120723 14
ANGLE/INPUT (A/IN): The threshold can’t be set by the operator: in fact the value is the result of
an external impulse through a proper contact (see paragraph “connections”).
This function can be very useful if the operator wants the screw to rotate a certain number of degrees
after reaching a position indicated by a precision instrument.
ANGLE/LEVER (A/LV): the threshold torque value can’t be set by the operator and the angle value
that appears on the display corresponds to the angle that is carried out starting from the moment in
which the lever is pressed. The angle has to be set in the "Ang. max ". If the lever is released before
reaching the set angle, the error "Error ang not OK" will be displayed.
INTERPRETATION OF ACOUSTIC SIGNALS
The control unit emits sounds which help you understand if the screwing has been carried out correctly or not.
When the torque is reached meeting all the parameters set, the control unit utters a 0.5 sec beep as
confirmation. In case of Program End, the unit will utter other two beeps. Instead, torque reached under min
time, during the Ramp time or under the Fast speed (see error signals on the display) will cause the control
unit to utter three beep sounds.