MANUAL
EDU 2AE/TOP - EDU 2AE/TOP/E -
EDU 2AE/TOP/TA 5.00
Torque range: 0.2-50 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
MODEL:
EDU 2AE/TOP
EDU2AE/TOP/E
EDU2AE/TOP/TA
CODE:
032000/TOP
032000/TOP/E
032000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 2,5 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU2AE/TOP and
EDU2AE/TOP/TA is in conformity with the following standards and other normative documents: 2006/42/CE,
LVD 2014/35/UE, EMCD 2014/30/UE, EN 280519, EN 60204-1, EN 61000-6-2, EN 61000-6-3.
It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, January 1
st
2020
Giovanni Colasante

Questions and Answers

  • M
    Madison DanielsSep 8, 2025
    How to resolve “Compensation error” on Kolver Controller?
    • C
      Courtney WardSep 8, 2025
      If the Kolver Controller displays “Compensation error” and a negative torque value is shown due to a high negative compensation value, increase or decrease the compensation value.
  • M
    Marissa ThomasAug 25, 2025
    Why does my Kolver Power Supply show “Protection 15A”?
    • S
      Steven HernandezAug 25, 2025
      The “Protection 15A” message on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 15A for at least 500 ms. To address this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • M
    Melissa MitchellAug 25, 2025
    What does “Protection 14p5A” mean on my Kolver Power Supply?
    • J
      Joseph CurryAug 26, 2025
      The message “Protection 14p5A” on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 14.5 A for at least 800 ms. To resolve this issue: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • A
    Ashley RichardsSep 18, 2025
    Why does my Kolver Control Unit display 'Protection 12A'?
    • D
      Dr. Jonathan WarnerSep 18, 2025
      The 'Protection 12A' message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is above 12A for at least 1 second. Here’s what you can do: - Decrease screwing time and check settings. - Avoid motor stalling. - Don't make unscrewing too heavy. - Check if the joint is too soft.
  • J
    jacob97Sep 9, 2025
    What does “Released lever error” mean on a Kolver Controller?
    • M
      Matthew JacksonSep 9, 2025
      If the Kolver Controller displays “Released lever error”, it indicates that the lever was released while tightening. This error can be enabled or disabled through the “PROGRAM-MENU”.
  • C
    Chad NelsonSep 13, 2025
    What causes “Error loosen torque” on Kolver Controller?
    • G
      Gary PaceSep 13, 2025
      If the Kolver Controller displays “Error loosen torque”, it means the torque signal is displayed while loosening (only if it’s set on “max”). This can happen if: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • D
    Dennis RojasSep 3, 2025
    How to fix Kolver EDU 2AE/TOP/E when “waiting connection” doesn’t turn into “system ready”?
    • T
      Tammy WillisSep 3, 2025
      If your Kolver Control Unit displays “waiting connection” and does not switch to “system ready” after being turned on, check the flat connector inside the unit.
  • C
    Christopher SnyderSep 3, 2025
    What to do if my Kolver Controller shows “Output Disabled”?
    • J
      Jose SmithSep 4, 2025
      If the Kolver Controller displays 'Output Disabled', it means the protection of output signals was activated because the maximum load (400mA) was exceeded. To resolve this, verify that the set load does not surpass the maximum allowed value. Then, restart the control unit to reset the error.
  • C
    Carol MeyerSep 23, 2025
    What to do if Kolver Control Unit displays 'Error min torque'?
    • J
      jean69Sep 23, 2025
      If your Kolver Control Unit displays 'Error min torque', it means the torque signal is displayed below the preset minimum torque. You should check parameters once again.
  • C
    Courtney MooreAug 29, 2025
    What to do if my Kolver EDU 2AE/TOP/E Control Unit displays “Output Disabled”?
    • K
      kevinskinnerAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.

Kolver EDU 2AE/TOP/E Specifications

General IconGeneral
Voltage24 VDC
ESD SafeYes
Weight1.3 kg
Input Voltage100-240 VAC
Output Voltage24 VDC
Operating Temperature0 - 40 °C
Torque Range (lbf.in)1.77 - 17.7 lbf.in
CommunicationRS-232
ProtectionOverload