MANUAL
EDU 2AE/TOP - EDU 2AE/TOP/E -
EDU 2AE/TOP/TA 5.00
Torque range: 0.2-50 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
MODEL:
EDU 2AE/TOP
EDU2AE/TOP/E
EDU2AE/TOP/TA
CODE:
032000/TOP
032000/TOP/E
032000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 2,5 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU2AE/TOP and
EDU2AE/TOP/TA is in conformity with the following standards and other normative documents: 2006/42/CE,
LVD 2014/35/UE, EMCD 2014/30/UE, EN 280519, EN 60204-1, EN 61000-6-2, EN 61000-6-3.
It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, January 1
st
2020
Giovanni Colasante

Questions and Answers

  • M
    mlaneAug 30, 2025
    Why does my Kolver EDU 2AE/TOP/E display “Protection 12A”?
    • K
      Kenneth GeorgeAug 30, 2025
      The “Protection 12A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 12 A for at least 1 second. To resolve this: * Reduce the cycle rate and check settings. * Avoid motor stalling. * Avoid unscrewing too heavily. * Check if the joint is too soft.
  • M
    Madison DanielsSep 8, 2025
    How to resolve “Compensation error” on Kolver Controller?
    • C
      Courtney WardSep 8, 2025
      If the Kolver Controller displays “Compensation error” and a negative torque value is shown due to a high negative compensation value, increase or decrease the compensation value.
  • C
    Courtney MooreAug 29, 2025
    What to do if my Kolver EDU 2AE/TOP/E Control Unit displays “Output Disabled”?
    • K
      kevinskinnerAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.
  • P
    psandovalSep 22, 2025
    What causes 'Reverse torque error' on Kolver Control Unit and how to fix it?
    • D
      david04Sep 22, 2025
      The 'Reverse torque error' on your Kolver Control Unit indicates that the torque signal is displayed while loosening (only if set on 'max'). This can happen because: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • C
    Christopher AndrewsSep 9, 2025
    What to do if Kolver Controller warns “Warning! No piece”?
    • K
      Katrina WalkerSep 9, 2025
      If the Kolver Controller displays “Warning! No piece” and the “missing piece” contact is enabled, check contact 2 on the CN2 connector.
  • C
    Chad NelsonSep 13, 2025
    What causes “Error loosen torque” on Kolver Controller?
    • G
      Gary PaceSep 13, 2025
      If the Kolver Controller displays “Error loosen torque”, it means the torque signal is displayed while loosening (only if it’s set on “max”). This can happen if: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • A
    Ashley RichardsSep 18, 2025
    Why does my Kolver Control Unit display 'Protection 12A'?
    • D
      Dr. Jonathan WarnerSep 18, 2025
      The 'Protection 12A' message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is above 12A for at least 1 second. Here’s what you can do: - Decrease screwing time and check settings. - Avoid motor stalling. - Don't make unscrewing too heavy. - Check if the joint is too soft.
  • G
    Gregory RayAug 27, 2025
    What to do if Kolver Power Supply displays “Error Torque Control”?
    • R
      Raymond DoyleAug 27, 2025
      If the Kolver Power Supply displays “Error Torque Control”, create a new screw. If the error persists, adjust the torque and speed settings.
  • C
    Chloe BrownAug 26, 2025
    How to fix “Protection 12A” error on Kolver Power Supply?
    • G
      Gregory MunozAug 26, 2025
      When the status bar of your Kolver Power Supply displays “Protection 12A”, it means the current on mosfets of bridge H is exceeding 12A for at least 1 second. To fix this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure unscrewing isn't too heavy. - Verify the joint isn't too soft.
  • M
    Melissa MitchellAug 25, 2025
    What does “Protection 14p5A” mean on my Kolver Power Supply?
    • J
      Joseph CurryAug 26, 2025
      The message “Protection 14p5A” on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 14.5 A for at least 800 ms. To resolve this issue: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.

Kolver EDU 2AE/TOP/E Specifications

General IconGeneral
Voltage24 VDC
ESD SafeYes
Weight1.3 kg
Input Voltage100-240 VAC
Output Voltage24 VDC
Operating Temperature0 - 40 °C
Torque Range (lbf.in)1.77 - 17.7 lbf.in
CommunicationRS-232
ProtectionOverload