EasyManua.ls Logo

Kolver EDU 2AE/TOP/E - User Manual

Kolver EDU 2AE/TOP/E
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MANUAL
EDU 2AE/TOP - EDU 2AE/TOP/E -
EDU 2AE/TOP/TA 5.00
Torque range: 0.2-50 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
MODEL:
EDU 2AE/TOP
EDU2AE/TOP/E
EDU2AE/TOP/TA
CODE:
032000/TOP
032000/TOP/E
032000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 2,5 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU2AE/TOP and
EDU2AE/TOP/TA is in conformity with the following standards and other normative documents: 2006/42/CE,
LVD 2014/35/UE, EMCD 2014/30/UE, EN 280519, EN 60204-1, EN 61000-6-2, EN 61000-6-3.
It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, January 1
st
2020
Giovanni Colasante

Questions and Answers

  • C
    Christina JohnsonAug 27, 2025
    Why am I getting a “Reverse torque error” on my Kolver Power Supply?
    • E
      eperezAug 27, 2025
      The “Reverse torque error” message appears on the status bar of the Kolver Power Supply when the torque signal is displayed while loosening, specifically when it’s set to “max”. This can be due to: - The screwdriver couldn’t loosen. - Motor stalling. - Loosening being too heavy.
  • J
    jefferyhunterAug 27, 2025
    What does “Compensation error” mean on Kolver Power Supply?
    • W
      williamsjosephAug 27, 2025
      If the Kolver Power Supply displays “Compensation error” on the status bar, it indicates a negative torque value is shown due to a high negative compensation value. To resolve this, increase or decrease the compensation value.
  • D
    Donald LawrenceAug 28, 2025
    What does “Warning! No piece” mean on Kolver Power Supply?
    • K
      Kathryn HuntAug 28, 2025
      If the Kolver Power Supply displays “Warning! No piece” on the status bar, and the “missing piece” contact is enabled, check contact 2 on the CN2 connector.
  • D
    Daniel GonzalezAug 28, 2025
    Why does my Kolver Control Unit display “Protection 15A”?
    • H
      hallkathrynAug 28, 2025
      The “Protection 15A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 15 A for at least 500 ms. To resolve this, try the following: * Reduce the cycle rate. * Check the settings. * Avoid motor stalling. * Avoid unscrewing too heavy.
  • C
    Courtney MooreAug 29, 2025
    What to do if my Kolver EDU 2AE/TOP/E Control Unit displays “Output Disabled”?
    • K
      kevinskinnerAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.
  • L
    Lindsay WrightAug 30, 2025
    Why does my Kolver EDU 2AE/TOP/E display “Protection 14p5A”?
    • J
      Joan BuchananAug 30, 2025
      The “Protection 14p5A” message appears on your Kolver Control Unit when the current on the mosfets of bridge H exceeds 14.5 A for at least 800 ms. Suggested solutions: 1. Reduce the cycle rate and check settings. 2. Avoid motor stalling. 3. Avoid unscrewing too heavily. 4. Check if the joint is too soft.
  • M
    mlaneAug 30, 2025
    Why does my Kolver EDU 2AE/TOP/E display “Protection 12A”?
    • K
      Kenneth GeorgeAug 30, 2025
      The “Protection 12A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 12 A for at least 1 second. To resolve this: * Reduce the cycle rate and check settings. * Avoid motor stalling. * Avoid unscrewing too heavily. * Check if the joint is too soft.
  • R
    Rachel RasmussenAug 25, 2025
    What to do if Kolver Power Supply shows “Output Disabled”?
    • R
      Rebekah WilliamsAug 25, 2025
      If the Kolver Power Supply displays “Output Disabled”, it means the protection of output signals was activated due to exceeding the maximum load (400mA). To resolve this, verify that the set load does not exceed the allowed maximum value. After checking the load, restart the control unit to reset the error.
  • A
    Amanda AdamsSep 1, 2025
    What to do if Kolver EDU 2AE/TOP/E Control Unit displays “Transmission error”?
    • R
      Richard TuckerSep 1, 2025
      If your Kolver Control Unit displays “Transmission error”, it means the data transmission from the display board to the motor board is incorrect. First, press ESC to retransmit the data. If the error persists, restart the control unit.
  • M
    michael41Sep 1, 2025
    What to do if Kolver EDU 2AE/TOP/E displays “Released lever error”?
    • C
      Christopher LeeSep 1, 2025
      If the “Released lever error” is displayed on the status bar of your Kolver Control Unit, it signifies that the lever was released while screwing. Note that this error can be enabled or disabled through the “PROGRAM-MENU”.

Kolver EDU 2AE/TOP/E Specifications

General IconGeneral
Voltage24 VDC
ESD SafeYes
Weight1.3 kg
Input Voltage100-240 VAC
Output Voltage24 VDC
Operating Temperature0 - 40 °C
Torque Range (lbf.in)1.77 - 17.7 lbf.in
CommunicationRS-232
ProtectionOverload

Related product manuals