MANUAL
EDU 2AE/TOP e EDU 2AE/TOP/TA
Torque range: 0.4-35 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
CONTROL UNIT MODEL: EDU 2AE TOP - EDU 2AE TOP/TA
CODE: 031000/TOP - 031000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
TRANSFORMER: 230V or 110VAC 50 Hz 40 V DC 200 VA FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 4 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU 2AE is in conformity with
the following standards and other normative documents: 2006/42/CE, 2006/95/CE, 2004/108/CE, EN 60745-1,
EN 60204-1, EN 61000-6-1, EN 61000-6-3.
It is also in conformity with the RoHS II normative.
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, May 2
nd
, 2013
Giovanni Colasante

Questions and Answers

  • C
    Chelsea RobersonSep 8, 2025
    How to resolve “Compensation error” on Kolver Controller?
    • K
      Kayla ReyesSep 8, 2025
      If the Kolver Controller displays “Compensation error” and a negative torque value is shown due to a high negative compensation value, increase or decrease the compensation value.
  • S
    Shawn PerryAug 25, 2025
    Why does my Kolver Power Supply show “Protection 15A”?
    • H
      Heidi JohnsonAug 25, 2025
      The “Protection 15A” message on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 15A for at least 500 ms. To address this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • C
    Claudia WallaceAug 25, 2025
    What does “Protection 14p5A” mean on my Kolver Power Supply?
    • B
      bellkyleAug 26, 2025
      The message “Protection 14p5A” on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 14.5 A for at least 800 ms. To resolve this issue: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • A
    Amy GrahamSep 18, 2025
    Why does my Kolver Control Unit display 'Protection 12A'?
    • M
      marktranSep 18, 2025
      The 'Protection 12A' message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is above 12A for at least 1 second. Here’s what you can do: - Decrease screwing time and check settings. - Avoid motor stalling. - Don't make unscrewing too heavy. - Check if the joint is too soft.
  • S
    srussellSep 8, 2025
    What does “Released lever error” mean on a Kolver Controller?
    • D
      drakejoannaSep 8, 2025
      If the Kolver Controller displays “Released lever error”, it indicates that the lever was released while tightening. This error can be enabled or disabled through the “PROGRAM-MENU”.
  • M
    Mrs. Sharon Chapman MDSep 13, 2025
    What causes “Error loosen torque” on Kolver Controller?
    • W
      Wesley MatthewsSep 13, 2025
      If the Kolver Controller displays “Error loosen torque”, it means the torque signal is displayed while loosening (only if it’s set on “max”). This can happen if: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • K
    Katherine ThompsonSep 3, 2025
    How to fix Kolver FAB when “waiting connection” doesn’t turn into “system ready”?
    • J
      Jason RossSep 3, 2025
      If your Kolver Control Unit displays “waiting connection” and does not switch to “system ready” after being turned on, check the flat connector inside the unit.
  • J
    James DavisSep 4, 2025
    What to do if my Kolver Controller shows “Output Disabled”?
    • B
      Bethany PetersenSep 4, 2025
      If the Kolver Controller displays 'Output Disabled', it means the protection of output signals was activated because the maximum load (400mA) was exceeded. To resolve this, verify that the set load does not surpass the maximum allowed value. Then, restart the control unit to reset the error.
  • M
    Misty SandersSep 23, 2025
    What to do if Kolver Control Unit displays 'Error min torque'?
    • M
      michaelfisherSep 23, 2025
      If your Kolver Control Unit displays 'Error min torque', it means the torque signal is displayed below the preset minimum torque. You should check parameters once again.
  • P
    Pamela BruceAug 29, 2025
    What to do if my Kolver FAB displays “Output Disabled”?
    • T
      Thomas CantuAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.

Kolver FAB Series Specifications

General IconGeneral
BrandKolver
ModelFAB Series
CategoryControl Unit