Vers. 111219 Page 9
The selection of the torque value is carried out by entering the digit cell by cell.
27) Ins. barcode: to scan a barcode and recall the desired program. To be used in combination with option
4. of the Sequence Menu.
IMPORTANT: Barcode can be ONLY numeric.
28) Serial PRT: Serial print: from OFF to 5.
When OFF, no print.
If it is set up to 5, this value identifies the number of line feeds between a string and another.
THE FOLLOWING MENU IS AVAILABLE ON T&A VERSION ONLY
29) Func T&A–T&A function mode: You can activate the Torque & Angle function. Set OFF when
you don’t need this function. When you set ON you can choose among six working conditions (see T&A
specific instructions).
30) Starting Tor – Starting torque: If T&A option is set on Tor mode (See T&A paragraph), you can
set the torque threshold the angle starts to be read from. When T&A is set on angle mode (see T&A
paragraph), you can set the torque threshold the angle starts to be carried out from.
31) Ang. min – Minimum angle: Minimum angle threshold. You can set it when T&A is set on Tor, T/in
or T/lv (see T&A specific instructions). The minimum angle the operator can set is 5°.
32) Ang. max - Maximum angle: Maximum angle threshold. You can set it when T&A is set on Tor,
T/in or T/lv (see T&A specific instructions). The maximum angle the operator can set is 29999°.
When T&A is set on Ang., A/in or A/lv mode, maximum angle corresponds to the angle that has to be
carried out.