EDU 2AE/TOP e EDU 2AE/TOP/TA
Torque range: 0.4-35 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
CONTROL UNIT MODEL: EDU 2AE TOP - EDU 2AE TOP/TA
CODE: 031000/TOP - 031000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
TRANSFORMER: 230V or 110VAC 50 Hz 40 V DC 200 VA FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 4 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU 2AE is in conformity with
the following standards and other normative documents: 2006/42/CE, 2006/95/CE, 2004/108/CE, EN 60745-1,
EN 60204-1, EN 61000-6-1, EN 61000-6-3.
It is also in conformity with the RoHS II normative.
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, May 2
nd
, 2013
Giovanni Colasante

Questions and Answers

  • F
    Francisco FitzgeraldAug 30, 2025
    Why does my Kolver FAB display “Protection 12A”?
    • C
      Christina FreemanAug 30, 2025
      The “Protection 12A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 12 A for at least 1 second. To resolve this: * Reduce the cycle rate and check settings. * Avoid motor stalling. * Avoid unscrewing too heavily. * Check if the joint is too soft.
  • C
    Chelsea RobersonSep 8, 2025
    How to resolve “Compensation error” on Kolver Controller?
    • K
      Kayla ReyesSep 8, 2025
      If the Kolver Controller displays “Compensation error” and a negative torque value is shown due to a high negative compensation value, increase or decrease the compensation value.
  • P
    Pamela BruceAug 29, 2025
    What to do if my Kolver FAB displays “Output Disabled”?
    • T
      Thomas CantuAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.
  • M
    Melody NielsenSep 22, 2025
    What causes 'Reverse torque error' on Kolver Control Unit and how to fix it?
    • A
      allison80Sep 22, 2025
      The 'Reverse torque error' on your Kolver Control Unit indicates that the torque signal is displayed while loosening (only if set on 'max'). This can happen because: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • J
    Justin ScottSep 9, 2025
    What to do if Kolver Controller warns “Warning! No piece”?
    • M
      Michael NunezSep 9, 2025
      If the Kolver Controller displays “Warning! No piece” and the “missing piece” contact is enabled, check contact 2 on the CN2 connector.
  • M
    Mrs. Sharon Chapman MDSep 13, 2025
    What causes “Error loosen torque” on Kolver Controller?
    • W
      Wesley MatthewsSep 13, 2025
      If the Kolver Controller displays “Error loosen torque”, it means the torque signal is displayed while loosening (only if it’s set on “max”). This can happen if: - The screwdriver couldn’t loosen. - You should avoid motor stalling. - Loosening is too heavy.
  • A
    Amy GrahamSep 18, 2025
    Why does my Kolver Control Unit display 'Protection 12A'?
    • M
      marktranSep 18, 2025
      The 'Protection 12A' message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is above 12A for at least 1 second. Here’s what you can do: - Decrease screwing time and check settings. - Avoid motor stalling. - Don't make unscrewing too heavy. - Check if the joint is too soft.
  • M
    matthew36Aug 27, 2025
    What to do if Kolver Power Supply displays “Error Torque Control”?
    • J
      John AdamsAug 27, 2025
      If the Kolver Power Supply displays “Error Torque Control”, create a new screw. If the error persists, adjust the torque and speed settings.
  • R
    Rachel BlankenshipAug 26, 2025
    How to fix “Protection 12A” error on Kolver Power Supply?
    • R
      Ryan JohnsonAug 26, 2025
      When the status bar of your Kolver Power Supply displays “Protection 12A”, it means the current on mosfets of bridge H is exceeding 12A for at least 1 second. To fix this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure unscrewing isn't too heavy. - Verify the joint isn't too soft.
  • C
    Claudia WallaceAug 25, 2025
    What does “Protection 14p5A” mean on my Kolver Power Supply?
    • B
      bellkyleAug 26, 2025
      The message “Protection 14p5A” on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 14.5 A for at least 800 ms. To resolve this issue: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.