MANUAL
EDU 2AE/TOP e EDU 2AE/TOP/TA
Torque range: 0.4-35 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
CONTROL UNIT MODEL: EDU 2AE TOP - EDU 2AE TOP/TA
CODE: 031000/TOP - 031000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
TRANSFORMER: 230V or 110VAC 50 Hz 40 V DC 200 VA FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 4 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU 2AE is in conformity with
the following standards and other normative documents: 2006/42/CE, 2006/95/CE, 2004/108/CE, EN 60745-1,
EN 60204-1, EN 61000-6-1, EN 61000-6-3.
It is also in conformity with the RoHS II normative.
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, May 2
nd
, 2013
Giovanni Colasante

Questions and Answers

  • C
    Curtis SullivanAug 27, 2025
    Why am I getting a “Reverse torque error” on my Kolver Power Supply?
    • B
      Brandon PayneAug 27, 2025
      The “Reverse torque error” message appears on the status bar of the Kolver Power Supply when the torque signal is displayed while loosening, specifically when it’s set to “max”. This can be due to: - The screwdriver couldn’t loosen. - Motor stalling. - Loosening being too heavy.
  • C
    Carol HardyAug 27, 2025
    What does “Compensation error” mean on Kolver Power Supply?
    • T
      Terri RoweAug 27, 2025
      If the Kolver Power Supply displays “Compensation error” on the status bar, it indicates a negative torque value is shown due to a high negative compensation value. To resolve this, increase or decrease the compensation value.
  • E
    Eddie BenitezAug 28, 2025
    What does “Warning! No piece” mean on Kolver Power Supply?
    • K
      Kyle ChavezAug 28, 2025
      If the Kolver Power Supply displays “Warning! No piece” on the status bar, and the “missing piece” contact is enabled, check contact 2 on the CN2 connector.
  • J
    Jeremiah SandovalAug 28, 2025
    Why does my Kolver Control Unit display “Protection 15A”?
    • D
      Daniel RiceAug 28, 2025
      The “Protection 15A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 15 A for at least 500 ms. To resolve this, try the following: * Reduce the cycle rate. * Check the settings. * Avoid motor stalling. * Avoid unscrewing too heavy.
  • P
    Pamela BruceAug 29, 2025
    What to do if my Kolver FAB displays “Output Disabled”?
    • T
      Thomas CantuAug 29, 2025
      The “Output Disabled” message on your Kolver Control Unit means that the protection of output signals was activated after exceeding the maximum load (400mA). To fix this: * Check that the set load does not exceed the maximum value. * Restart the control unit to reset the error.
  • N
    nsmithAug 30, 2025
    Why does my Kolver FAB display “Protection 14p5A”?
    • A
      Amanda WarrenAug 30, 2025
      The “Protection 14p5A” message appears on your Kolver Control Unit when the current on the mosfets of bridge H exceeds 14.5 A for at least 800 ms. Suggested solutions: 1. Reduce the cycle rate and check settings. 2. Avoid motor stalling. 3. Avoid unscrewing too heavily. 4. Check if the joint is too soft.
  • F
    Francisco FitzgeraldAug 30, 2025
    Why does my Kolver FAB display “Protection 12A”?
    • C
      Christina FreemanAug 30, 2025
      The “Protection 12A” message on your Kolver Control Unit indicates that the current on the mosfets of bridge H is greater than 12 A for at least 1 second. To resolve this: * Reduce the cycle rate and check settings. * Avoid motor stalling. * Avoid unscrewing too heavily. * Check if the joint is too soft.
  • S
    Susan MooreAug 25, 2025
    What to do if Kolver Power Supply shows “Output Disabled”?
    • D
      Dr. Jermaine SandovalAug 25, 2025
      If the Kolver Power Supply displays “Output Disabled”, it means the protection of output signals was activated due to exceeding the maximum load (400mA). To resolve this, verify that the set load does not exceed the allowed maximum value. After checking the load, restart the control unit to reset the error.
  • J
    James KlineAug 31, 2025
    What to do if Kolver FAB displays “Transmission error”?
    • M
      Micheal ArnoldSep 1, 2025
      If your Kolver Control Unit displays “Transmission error”, it means the data transmission from the display board to the motor board is incorrect. First, press ESC to retransmit the data. If the error persists, restart the control unit.
  • T
    Tonya SmithSep 1, 2025
    What to do if Kolver FAB displays “Released lever error”?
    • A
      Austin HernandezSep 1, 2025
      If the “Released lever error” is displayed on the status bar of your Kolver Control Unit, it signifies that the lever was released while screwing. Note that this error can be enabled or disabled through the “PROGRAM-MENU”.