MANUAL
EDU 2AE/TOP e EDU 2AE/TOP/TA
Torque range: 0.4-35 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
CONTROL UNIT MODEL: EDU 2AE TOP - EDU 2AE TOP/TA
CODE: 031000/TOP - 031000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
TRANSFORMER: 230V or 110VAC 50 Hz 40 V DC 200 VA FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 4 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU 2AE is in conformity with
the following standards and other normative documents: 2006/42/CE, 2006/95/CE, 2004/108/CE, EN 60745-1,
EN 60204-1, EN 61000-6-1, EN 61000-6-3.
It is also in conformity with the RoHS II normative.
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, May 2
nd
, 2013
Giovanni Colasante

Questions and Answers

  • C
    christy87Sep 22, 2025
    What to do if Kolver Control Unit displays 'tightened screw'?
    • D
      Donna MaxwellSep 22, 2025
      If your Kolver Control Unit displays 'tightened screw', it means the torque signal is displayed during the motor startup process which lasted 0.3 sec. You should check parameters once again.
  • J
    julie56Sep 23, 2025
    What does 'Compensation error' mean on Kolver Control Unit and how to fix it?
    • S
      Steven SantosSep 23, 2025
      The 'Compensation error' on your Kolver Control Unit means a negative torque value is displayed due to a high negative compensation value. To resolve it, increase or decrease the compensation value.
  • V
    Valerie RiveraSep 23, 2025
    What does 'Released lever error' mean on Kolver Control Unit?
    • M
      Mr. David MoranSep 23, 2025
      The 'Released lever error' on the Kolver Control Unit indicates that the lever was released while tightening. This error can be enabled or disabled through the PROGRAM-MENU (see point 18 on the program menu).
  • R
    Ricardo BrownSep 23, 2025
    What to do if Kolver Control Unit displays 'Warning! No piece'?
    • N
      Nicole MillerSep 23, 2025
      If your Kolver Control Unit displays 'Warning! No piece', it means the 'missing piece' contact is enabled. Check contact 2 on the CN2 connector.
  • M
    Misty SandersSep 23, 2025
    What to do if Kolver Control Unit displays 'Error min torque'?
    • M
      michaelfisherSep 23, 2025
      If your Kolver Control Unit displays 'Error min torque', it means the torque signal is displayed below the preset minimum torque. You should check parameters once again.
  • T
    Tanya WebbAug 31, 2025
    What to do if Kolver FAB displays “Error unscrew torque”?
    • M
      Michele ArellanoAug 31, 2025
      The “Error unscrew torque” message on your Kolver Control Unit indicates that the torque signal is displayed while unscrewing, but only if it’s set on “max”. This means that the screwdriver couldn’t unscrew. To resolve this: * Avoid motor stalling. * Avoid unscrewing too heavy.
  • S
    Shawn PerryAug 25, 2025
    Why does my Kolver Power Supply show “Protection 15A”?
    • H
      Heidi JohnsonAug 25, 2025
      The “Protection 15A” message on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 15A for at least 500 ms. To address this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • C
    Claudia WallaceAug 25, 2025
    What does “Protection 14p5A” mean on my Kolver Power Supply?
    • B
      bellkyleAug 26, 2025
      The message “Protection 14p5A” on the Kolver Power Supply status bar indicates that the current on mosfets of bridge H is greater than 14.5 A for at least 800 ms. To resolve this issue: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure that unscrewing is not too heavy. - Check if the joint is too soft.
  • R
    Rachel BlankenshipAug 26, 2025
    How to fix “Protection 12A” error on Kolver Power Supply?
    • R
      Ryan JohnsonAug 26, 2025
      When the status bar of your Kolver Power Supply displays “Protection 12A”, it means the current on mosfets of bridge H is exceeding 12A for at least 1 second. To fix this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure unscrewing isn't too heavy. - Verify the joint isn't too soft.
  • M
    matthew36Aug 27, 2025
    What to do if Kolver Power Supply displays “Error Torque Control”?
    • J
      John AdamsAug 27, 2025
      If the Kolver Power Supply displays “Error Torque Control”, create a new screw. If the error persists, adjust the torque and speed settings.