METHOD FOR ADJUSTING BUCKET CLEARANCE
kk
WARNING
It is dangerous if the work equipment moves by mistake
when adjusting the bucket clearance.
Lower the work equipment to the ground, set it in a stable
condition, stop the engine, and set the lock lever securely
to LOCK position (L).
1.
Set the work equipment in the position shown in the figure,
then stop the engine and set the lock lever to LOCK posi-
tion (L).
A: Arm
B: Bucket
2.
Shift O-ring (1) and measure the amount of play "a".
REMARK
Measurement is easier if you move the bucket to one side
so that all the play can be measured at one place (the right
side in the figure).
Use a clearance gauge for easy and accurate measure-
ment.
3.
Loosen plate mounting bolts (2) (4 pieces) and loosen
plate (3).
The shim is a split type, so the work can be performed
without removing the bolts.
4.
Remove shim (4) corresponding to the amount of play "a".
Shim (4) is a set of 2 pieces. The thickness of each piece
of shim (4) is 0.5 mm.
When play "a" is smaller than 1 shim, do not adjust it by
tightening bolts (2).
5.
Tighten bolts (2) (4 pieces).
If bolts (2) are too stiff to tighten, pull out pin stopper bolt
(5) for easier tightening.
METHOD FOR CHECKING WINDOW WASHER FLUID LEVEL, ADDING FLUID
If air is in the window washer fluid, check the fluid level in window washer tank (1).
MAINTENANCE MAINTENANCE PROCEDURE
4-33
WENAM00042