V3F25/18 drive
Installation Instruction
© 2004 KONE Corporation AM-11.65.020
All rights reserved. 1 (42) (E) 2004-01-08
COMMISSIONING INSTRUCTION FOR DRIVE SYSTEMS V
3
F25
AND V
3
F18
TABLE OF CONTENTS
1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Validity of the instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Abbreviations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 General working safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Electrical working safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 INTRODUCTION OF COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Common boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Panels in the elevator shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 Panels in the machine room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 INITIAL COMMISSIONING OF THE MACHINE (WITHOUT ROPES) . . . . . . . . . . . . . . . . . .11
4.1 Prerequisites and preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4.2 Setting parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3 Setting the input information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.4 Initial setting of the resolver angle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5 COMMISSIONING OF THE MACHINE AFTER ROPING . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 LWD setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2 Repeating the resolver angle setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3 Shaft setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.4 Fine tuning the resolver angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6 FINE ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.1 Drive adjustments and checks (speed control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2 Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.3 Jerky start or roll back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.4 Stopping (final rounding to the floor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.5 Testing with heavy loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.6 Balance measurement in elevators with V
3
F18 drive and MAP panel . . . . . . . . . . . 31
6.7 Balance measurement in elevators with V
3
F25 drive . . . . . . . . . . . . . . . . . . . . . . . . 32
7 APPROVALS AND VERSION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
APPENDIX A. Returning the initial settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
APPENDIX B. Buzzer warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
APPENDIX C. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
APPENDIX D. Parameter table 779980. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Other manuals for Kone V3F25

Question and Answer IconNeed help?

Do you have a question about the Kone V3F25 and is the answer not in the manual?

Summary

1 GENERAL

1.1 Validity of the instruction

Specifies the validity of the installation instruction for V3F18 and V3F25 drive modules.

1.2 Related documents

Lists references to other elevator level instructions and documents for commissioning.

1.3 Abbreviations

Provides a list of abbreviations used in the document, such as CMB, LWD, etc.

2 SAFETY

2.1 General working safety

Covers general safety precautions, including fall arrest systems and asking superiors for guidance.

2.2 Electrical working safety

Details safe practices for electrical work, including power disconnection and verification.

3 INTRODUCTION OF COMPONENTS

3.1 Common boards

Describes the HCB board (781380G01), its layout, and connections.

3.2 Panels in the elevator shaft

Illustrates and lists panels found in the elevator shaft for different elevator types.

3.3 Panels in the machine room

Shows and lists panels located in the machine room for MiniSpace elevators.

4 INITIAL COMMISSIONING OF THE MACHINE (WITHOUT ROPES)

4.1 Prerequisites and preparations

Outlines necessary checks before commissioning, including mechanical obstructions and cable routing.

4.2 Setting parameters

Details how to enter the drive menu and set elevator-dependent parameters.

4.3 Setting the input information

Explains how to adjust the tacho test potentiometer and check MXTORQ.

4.4 Initial setting of the resolver angle

Guides through the process of setting the resolver angle using Resolver AutoDetect.

5 COMMISSIONING OF THE MACHINE AFTER ROPING

5.1 LWD setup

Describes how to check and set up the Load Weighing Device (LWD).

5.2 Repeating the resolver angle setting

Instructions for repeating the resolver angle setting after ropes are installed.

5.3 Shaft setup

Details the procedure for setting up the elevator shaft parameters.

5.4 Fine tuning the resolver angle

Explains how to fine-tune the resolver angle for optimal performance.

6 FINE ADJUSTMENTS

6.1 Drive adjustments and checks (speed control)

Covers adjustments to P factor, I factor, and Tacho filter time for ride comfort.

6.2 Starting

Discusses adjusting the start delay parameter for smooth starting.

6.3 Jerky start or roll back

Provides steps to address jerky starts or roll back issues.

6.4 Stopping (final rounding to the floor)

Explains how to adjust final jerk distance for smoother stopping.

6.5 Testing with heavy loads

Details the procedure for testing the drive with heavy loads.

6.6 Balance measurement in elevators with V3 F18 drive and MAP panel

Describes how to measure motor current for balance on V3F18 drive systems.

6.7 Balance measurement in elevators with V3 F25 drive

Describes how to measure motor current for balance on V3F25 drive systems.

7 APPROVALS AND VERSION HISTORY

Appendix A. Returning the initial settings

Appendix B. Buzzer warnings

C. Troubleshooting

C.1 Connections

Guides on checking connections for components like XSR1 and XM1 if the motor doesn't rotate.

C.2 Drive fault codes

Lists drive faults, symptoms, and recommended actions for troubleshooting.

Appendix D. Parameter table 779980

Kone V3F25 Specifications

General IconGeneral
BrandKone
ModelV3F25
CategoryServo Drives
LanguageEnglish