V3F25/18 drive
Installation Instruction
© 2004 KONE Corporation AM-11.65.020
All rights reserved. 19 (42) (E) 2004-01-08
4.4 Initial setting of the resolver angle
The resolver angle should always be set without having suspension ropes installed.
If the ropes are installed, the recommended unbalance is 50 %. Allowed unbalance is
30...70 %.
If ropes are installed, the LWD must be adjusted before setting the resolver angle.
If no ropes, parameter
(5_1) must read L 50. If parameter (5_1) does not read L 50, select
parameter
(6_74) and set value to -1 and press select. Default value for the software
based LWD scaling is 50 %.
4.4.1 Setting the resolver angle
WARNING
Check that there is nothing in contact with the machinery traction sheave or ropes.
Step Action Note
1 Activate the automatic resolver angle
setting using
Resolver AutoDetect
(6_70)
parameter in menu.
After the activation the buzzer in the
drive starts to beep [ * * * * ].
2 Drive the car in
heavy direction (up
direction, if no ropes) until it stops.
For a successful run the motor sheave
turns about 1.5 rotations.
LISTEN TO THE BEEPS:
[ * * * * ] = Drive requests you to drive
in heavy direction.
If you tried four times without any
success, change the
motor rotation
direction:
turn the
power OFF, wait 5
minutes and
swap two phases (U and V) in
the motor cable.
[ __ * * * ] = the angle was not found.
3 After successful drive in the heavy
direction drive the car in
light direction
(down direction, if no ropes) until it
stops.
[ * * ] = Drive in light direction.
4 Repeat the drive in
heavy direction. [ * * * * ] = Drive in heavy direction.
5 Repeat the drive in
light direction. [ * * ] = Drive in light direction.
6 Listen to the sound fo
possible fault
detected during the adjustment.
[ __ * * ] = Fault
If a fault occurs, switch the power
OFF and ON.
Possible reason for the
fault is wrong LWD setting, the LWD
setting is missing or the elevator is too
much out of balance.