OTHER CONTROLS
2-37
II UNIT EXPLANATION
11. OTHER CONTROLS
11.1 Parts Energized When the Main Power Switch is OFF
The follwing components are powered regardless of whether the SW1 (Main power switch) is on or off,
provided that the power cord remains plugged in.
A. CBR 1 and CBR 2 (Circuit breakers/1 and /2)
The circuit breakers serve to protect internal components against damage from short circuit. If current
exceeds the specified value, the circuit breaker(s) will go off, cutting the power to the system.
B. NF (Noise filter)
This filter reduces noises that enter through the power line.
C. DCPS (DC power source)
This supplies power to each unit, and also controls the ON/OFF state of the fixing heater lamp.
SW1
DCPS
NF
AC(H)
AC(N)
CBR1
CBR2