116 Part Number STH063 9/17

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser

Freeze Time Harvest
Time

  
 13.3-15.5 16.0-18.6 18.1-21.0
1.0-2.5
 15.7-18.2 18.1-21.0 19.8-22.9
 17.3-20.1 19.3-22.4 21.8-25.2
 19.3-22.4 21.3-24.6 23.6-27.3
 21.8-25.2 23.0-26.6 25.7-29.7
Times in minutes
24 Hour Ice Production
Air Temp. Entering


  
 330 280 250
 285 250 230
 260 230 210
 235 215 195
 210 200 180
Based on average ice slab weight of 3.40 – 3.90 lb (1.54 – 1.77 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 300-335 70-38 160-180 150-175
 310-340 75-40 180-200 150-175
 315-360 80-42 185-210 150-175
 320-375 90-44 190-215 150-175
 420-510 100-49 300-330 200-250
 450-540 120-52 355-370 270-290
Suction pressure drops gradually throughout the freeze cycle