Part Number STH063 9/17 125

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser

Freeze Time Harvest
Time

  
 10.2-11.0 11.6-12.5 12.6-13.6
1.0-2.5
 11.2-12.1 12.2-13.2 13.4-14.4
 12.1-13.0 13.9-14.9 14.8-15.9
 13.2-14.2 14.2-15.3 16.2-17.4
 14.3-15.4 16.3-17.6 17.8-19.2
Times in minutes
24 Hour Ice Production
Air Temp. Entering


  
 890 800 740
 820 760 700
 770 680 640
 710 665 590
 660 585 540
Based on average ice slab weight of 7.25 – 7.75 lb (3.3 – 3.5 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 280-350 60-36 135-150 100-140
 280-350 65-36 135-155 105-140
 300-400 70-38 150-180 105-150
 350-420 75-39 160-210 120-150
 425-520 80-40 170-240 130-155
 440-540 85-41 190-250 135-160
Suction pressure drops gradually throughout the freeze cycle