Part Number STH063 9/17 117

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser

Freeze Time Harvest
Time

  
 9.6-11.3 10.4-12.2 12.5-14.5
1.0-2.5
 10.2-11.9 11.2-13.1 14.0-16.3
 11.1-12.9 12.7-14.8 14.8-17.2
 12.1-14.1 14.3-16.6 16.3-18.9
 14.0-16.3 15.7-18.2 17.0-19.7
Times in minutes
24 Hour Ice Production
Air Temp. Entering


  
 440 410 350
 420 385 315
 390 345 300
 360 310 275
 315 285 265
Based on average ice slab weight of 3.40 – 3.90 lb (1.54 – 1.77 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 260-320 55-32 130-200 90-140
 275-340 60-33 150-200 100-140
 285-395 65-34 170-230 105-165
 335-410 70-35 190-250 110-175
 400-500 80-40 280-340 160-220
 450-520 85-42 320-360 190-235
Suction pressure drops gradually throughout the freeze cycle