Part Number STH063 9/17 123

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser

Freeze Time Harvest
Time

  
 7.3-8.6 8.7-10.2 9.3-10.9
1.0-2.5
 8.0-9.4 9.2-10.8 10.4-12.2
 8.8-10.4 9.7-11.4 11.7-13.7
 9.8-11.5 10.9-12.8 13.4-15.6
 11.0-12.9 12.3-14.4 14.3-16.7
Times in minutes
24 Hour Ice Production
Air Temp. Entering


  
 675 585 550
 625 555 500
 575 530 450
 525 480 400
 475 430 375
Based on average ice slab weight of4.125 – 4.75 lb (1.87 – 2.15 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 260-340 60-28 150-175 115-130
 275-350 65-30 165-200 115-130
 275-380 70-31 175-200 115-135
 350-415 75-35 185-200 135-145
 380-520 80-36 200-215 140-160
 440-540 80-36 210-220 155-175
Suction pressure drops gradually throughout the freeze cycle