The fault code and its comments are displayed as follows:
Water Curtain failure or Ice Full
Switch
Sleeping mode will recover after
the water curtain is reset
Protective shutdown and retry
every 30 mins
Contestation Sensor Open
Circuit
Error light comes on every 5
seconds
Condensation Sensor Short
Circuit
Error light comes on every 5
seconds
Water Level Control failure
Maintenance
Frequently clean the environment around the
ice machine to keep it clean. Do not block the
vents.
The outer enclosure should be cleaned with
a mild detergent and then wiped clean. If
necessary, use commercial stainless steel
cleaners and polishes.
The filter element should be inspected
regularly. It is recommended to replace filter
element every month to every 3 to 6 months.
The inside of the ice storage bin can be
washed with water and solution.
For the air-cooled ice maker, the condenser
should be cleaned every three weeks. Use a
soft brush or a vacuum cleaner with a brush
to brush it up and down along the fin
direction, to avoid damage to the fins and
further affecting the cooling effect.
The condenser filter should be cleaned every
2 weeks.