En-6
Meter display setting
You can specify the display pattern that’s shown on the meter’s display. You can choose one of four dis-
play patterns.
e default setting is “1: Regular meter”.
1
. Press the DISPLAY button.
e current setting is shown for several seconds on the display (lit → blinking).
2
. While this setting is shown, press the DISPLAY button to select the desired display pattern.
e setting will change each time you press the button.
1: Regular meter
Tune your instrument so that the center LED of the meter display is lit up.
e LED illumination will move from the center toward the right if the note is sharp, or from the
center toward the le if the note is at.
2: Strobe meter
Tune your instrument so that the illumination stops owing in the meter display. e illumination
will ow from le to right if the note is sharp, or from right to le if the note is at.
3: Half-strobe meter
Tune your instrument so that the stream stops and only the center LED is lit up. e right side of
the meter display will strobe if the note is sharp, and the le side of the meter display will strobe if
the note is at. When the pitch is correct, only the center LED will light up.
4. Focus meter
is mode enlarges the meter display within a ±10 cent range, for even more precise tuning.
Tune your instrument so that the center LED of the meter display is lit up.
When the tuning of the inputted note is within ±10 cents, the POWER ON LED changes to red
and the meter changes color. Also, the meter view enlarges to show the ±10 cent range.
e meter returns to the regular display when the tuning falls outside of the ±10 cent range.
3
. When you’ve chosen the desired setting, wait for two seconds without pressing any buttons.
e display indication will blink several times, and the meter display setting will be made. e
tuner will then return to its normal state, allowing you to tune.