7.
CHECK
AND
ADJUSTMENT
PROCEDURE
1.
Power
Supply
Voltage
Check
Connect a
Digital
Volt
Meter
(DVM)
to
TPs
on
KLM-6000
and
confirm
if
the
voltage
at
each
test
point
is
within
the
ranges
as
shown
below.
2.
Modulation
Check
The
settings
are
as
follows.
Mode
Sw.
=
separate
1)
Modulation
Connect
an
Oscilloscope
(DC
2v/div,
50ms/div)
to
TP-6A
and
TP-6B
on
KLM-6001
and
confirm
modulation
waveform
refering
to
the
chart
below.
Fig.
1 (DC
Changes)
Fig.
2
(Amplitude
changes)
Fig.
3
(Frequency
changes)
2)
Modulation
LED
lighting
Adjust
the
FREQ
volume
of
UNIT
A
and
B
to
"5",
and
check
each
LED
by
following
procedure
below.
©
Mode
Sw.:
IN
PHASE
Add
modulation
on
both
channels
and
confirm
if
both
are
syncronized
in
same
phase.
(2)
Mode
Sw.:
SEPARATE
Confirm
if
the
modulation
on
each
unit
is
controlled
independently.
<3>
Mode
Sw.:
OUT
PHASE
Add
modulation
on
both
channels
and
confirm
if
both
are
syncronized
in
inverted
phase.
10