5.
Clock
Check
and
Adjustment.
Set
as
above,
then:
1)
Set
FACTOR A
to
xO.25
2)
Connect
a
FREQUENCY
COUNTER
to
TP-4A
on
KLM-6000
and
confirm
if
the
value
is
170.64KHz
±8KHz.
3)
Adjust
VR105
if
necessary.
4)
Set
FACTOR
A
to
x
1
and
confirm
if
the
value
is
42.66KHz
±2KHz.
5)
Adjust
VR104
if
necessary.
6)
Change
FACTOR
A
from
x
0.25
to
x
1
to
confirm
if
the
value
are
in
the
range
specified
as
above.
Repeat
2)
-
4)
till
you
get
correct
value.
7)
Do
the
same
adjustment
for
UNIT
B
usnig
VR204
and
VR205.
~
ir
Note:
]
i
Above
values
are
for
under
20°C.
In
case
of
'
!
-40°C,
±10%
deviation
is
allowable.
6.
Analog
Compressor/Expnder
Check
and
Adjustment.
Set
as
above,
then:
1)
Input
a
Tone
Burst
wave
(400Hz,
-40dBm,
sine
waveform)
to
SDD-1200
UNIT
A
and
confirm
waveform
(fig.
5)
with
an
Oscilloscope
(DC
0.5v/div,
10ms/div)
connecting
to
MIX
OUTPUT.
2)
Confirm
if
the
DC
fluctuation
of
*3
shown
in
Fig.
5
is
minimized.
Adjust
VR102
on
KLM-6000
if
necessary.
3)
Confirm
if
the
linearity
of
*2
shown
in
fig.
5
is
almost
linear.
Adjust
VR103
on
KLM-6000
if
necessary.
12