Install KIT-400 using one of the following methods:
• Attach the rubber feet and place the unit on a flat surface.
• Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see www.kramerav.com/downloads/KIT-400).
• Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/product/KIT-400).
• Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
• Avoid uneven mechanical loading.
• Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
• Reliable earthing of rack-mounted equipment should be maintained.
• Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your KIT-400.
Connecting the audio output
Wiring the RJ-45 connectors
To a balanced
stereo audio
acceptor:
This section defines the TP pinout, using
a straight pin-to-pin cable with RJ-45
connectors.
To an unbalanced
stereo audio
acceptor:
For HDBT cables, it is recommended
that the cable ground shielding be
connected/soldered to the connector
shield.
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/KIT-400.
Using third-party cables may cause damage!
Setting the KIT-400T DIP-switches
A switch that is down is on; a switch that is up is off. By default, all the switches are up (off). After changing a DIP-switch you
must power cycle the device to implement the change.
DIP-switch 1 set to off (up).
DIP-switch 2 set to off (up).
Audio Switching Selection
Automatic – Priority selection: Embedded HDMI analog Audio In (high to low priority).
Automatic – Priority selection: Analog Audio In embedded HDMI (high to low priority).
To power the devices:
1. Set the PoC switches to ON on both
devices.
2. Connect the power adapter to one of the
devices (KIT-400T or KIT-400R).
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
• For products with relay terminals and GPI\O ports, please refer to the permitted rating for
an external connection, located next to the terminal or in the User Manual.
• There are no operator serviceable parts inside the unit.
Warning:
• Failure to use PoC and power connector correctly may destroy the devices!
• Use only the power cord that is supplied with the unit.
Disconnect the power and unplug the unit from the wall before installing.