EasyManua.ls Logo

Kramer TP-580CT - Connecting to TP-580 CT Via RS-232; Wiring RJ-45 Connectors; Setting the DIP-Switches

Kramer TP-580CT
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
TP-580CT Connecting TP-580CT
7
Connecting to TP-580CT via RS-232
You can connect to TP-580CT via an RS-232 connection using, for example, a PC.
TP-580CT features an RS-232 3-pin terminal block connector allowing the RS-232 to control
TP-580CT.
Connect the RS-232 terminal block on the rear panel of TP-580CT to a PC/controller, as
follows:
From the RS-232 9-pin D-sub serial port connect:
Pin 2 to the TX pin on the TP-580CT RS-232 terminal block
Pin 3 to the RX pin on the TP-580CT RS-232 terminal
block
Pin 5 to the G pin on the TP-580CT RS-232 terminal block
RS-232 Device TP-580CT
Wiring RJ-45 Connectors
This section defines the HDBT pinout, using a straight pin-to-pin cable with RJ-45 connectors.
For HDBT cables, it is recommended that the cable ground shielding be connected/soldered
to the connector shield.
EIA /TIA 568B
PIN
Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
Setting the DIP-Switches
Set DIP-switches. Changes in DIP-switch settings apply immediately.
All DIP-switches are set to OFF (up) by default.
DIP #
Description
State
1
IR output
modulation
OFF (up) default
IR pass-through is disabled (38KHz modulation to IR
output signal is added).
ON (down)
IR pass-through is enabled.
2
OFF (up) default
Normal operation.
ON (down)
FW upgrade via RS-232 is enabled.