Step 5: Operate via the front panel buttons and via the: 
WWW.KRAMERAV.COM
IR Remote Embedded Web Page
Step 4: Connect the power
Connect AC power to the rear of the   switch on its power and then switch on 
the power on each device. 
VS-62HA, 
RS-232 and Ethernet
Protocol   3000 (Default)  Legacy 
Baud Rate:  115,200  9,600 
Data Bits:  8  8 
Stop Bits:  1  1 
Parity:  None  None 
Command Format:  ASCII  ASCII 
Example (Set display mode to Picture in Picture):  #Y 0,110,1<CR>  >Y 0 110 1<CR> 
To reset the IP settings to the factory reset values, power cycle the device while holding in the Ethernet Reset button, located on the 
rear panel of the unit 
IP Address:   192.168.1.39 
Subnet mask:  255.255.000.000 
Default gateway:  000.000.000.000 
TCP Port #:   5000 
UDP Port #:   50000 
Maximum UDP Ports:   10 
Maximum TCP Ports:   4 
Web page password  1234 
Front panel buttons  Turn power off. Turn power on again while holding the RESET TO XGA/720p front panel button. 
The LEDs blink. Full factory reset is complete once the LEDs cease to blink and react normally. 
Note that Full Factory reset includes Ethernet reset as well 
OSD  Factory Reset through the Misc menu item 
Web pages  Factory reset via the Device Settings embedded Web page 
Protocol 3000  Use “Factory” command or #Y 0,771,1<CR>