EasyManua.ls Logo

Kramer VS-44DT

Kramer VS-44DT
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER MANUAL
MODEL:
VS-44DT
4x4 HDMI/HDBT Matrix Switcher with PoE
P/N: 2900-300470 Rev 1
www.KramerAV.com

Table of Contents

Other manuals for Kramer VS-44DT

Question and Answer IconNeed help?

Do you have a question about the Kramer VS-44DT and is the answer not in the manual?

Kramer VS-44DT Specifications

General IconGeneral
CategoryMatrix Switcher
Video Inputs4
Video Outputs4
Max Resolution4K@60Hz (4:4:4)
Max. Data Rate18 Gbps
HDBaseT CertifiedYes
Audio EmbeddingYes
Power Consumption20W
HDCP Compliance2.2
RangeUp to 100m
AudioEmbedded
ControlRS-232, Ethernet
Size1U
Power Supply100-240V AC, 50/60Hz
Signal TypeHDMI
Connector TypeHDMI

Summary

VS-44 DT Quick Start Guide

Package Contents Check

List of items included in the VS-44DT package.

VS-44 DT Front Panel Overview

Overview of the VS-44DT front panel features and functions.

VS-44 DT Installation Guide

Rack Installation Procedure

Instructions for installing the VS-44DT unit into a rack.

VS-44 DT Operation and Setup

Connecting Inputs and Outputs

Steps for connecting AV sources and displays to the VS-44DT.

Connecting Power Supply

Procedure for connecting the VS-44DT to a power source.

Setting Operation Parameters via Menu

Guide to setting device parameters using the front panel menu.

VS-44 DT Remote Operation and Technical Specs

Operating via Front Panel Display

Using the front panel menu and buttons for operation.

Technical Specifications

Detailed technical specifications of the VS-44DT matrix switcher.

Introduction to Kramer and VS-44 DT

Company and Product Overview

Introduction to Kramer Electronics and the VS-44DT switcher.

Getting Started with VS-44 DT

Achieving Best Performance Tips

Tips for optimal performance and signal quality.

Safety Instructions and Warnings

Important safety precautions for using the device.

VS-44 DT Cable and Recycling Information

Kramer Cable Recommendations

Information on Kramer's recommended cables for optimal performance.

Recycling Kramer Products

Information on environmentally responsible product disposal.

VS-44 DT Product Overview

Key Features of the VS-44 DT

Comprehensive list of the VS-44DT's capabilities and functions.

VS-44 DT Technology and Definition

About HDBaseT Technology

Explanation of HDBaseT connectivity technology.

Defining the VS-44 DT Matrix Switcher

Detailed definition of the VS-44DT product.

VS-44 DT Rack Installation Guide

Rack Mounting Precautions and Guidelines

Important safety and installation guidelines for rack mounting.

Connecting the VS-44 DT

Example Connection Diagram

Visual guide showing typical input/output connections for the VS-44DT.

VS-44 DT Serial and Ethernet Connections

Connecting to a Serial Controller

Instructions for connecting the VS-44DT via RS-232 to a serial controller.

Connecting to Serial Data SourceAcceptor

Connecting the VS-44DT via RS-232 to data sources/acceptors.

VS-44 DT Ethernet Connectivity

Connecting Directly to a PC via Ethernet

Procedure for direct Ethernet connection to a PC.

VS-44 DT RJ-45 and Ethernet Setup

Wiring the RJ-45 Connectors

Pinout and wiring details for RJ-45 connectors.

Connecting via Network Hub or Switch

Connecting the VS-44DT to a network hub or switch.

Operating the VS-44 DT

Switching Inputs to Outputs

How to switch inputs to outputs on the device front panel.

VS-44 DT Preset Configurations

Storing and Recalling Preset Configurations

Saving and recalling device configurations using presets.

VS-44 DT Output Management

Acquiring EDID Data

Procedure to acquire and assign EDID data.

Disconnecting Outputs

How to disconnect outputs from the VS-44DT.

VS-44 DT Device Configuration

Resetting to Factory Default Configuration

Steps to reset the device to factory defaults.

VS-44 DT Front Panel Control

Locking and Unlocking the Front Panel

How to lock/unlock front panel buttons.

Configuring the VS-44 DT via Menu

Using the Menu System

Navigating the device's menu system for configuration.

Setting Audio Source and Volume

Configuring audio settings and volume levels.

VS-44 DT Network and RS-232 Settings

Setting RS-232 Routing

Configuring RS-232 data routing between ports.

Setting Auto Switching

Enabling or disabling automatic input switching.

Setting Network Parameters

Configuring network (IP, DHCP) parameters.

Ethernet Status Sub-menu

Displaying TCP/IP communication parameters.

VS-44 DT Firmware and IP Configuration

FW Version Display

Displaying the current firmware version.

Reset to Default Parameters

Resetting device to default factory parameters.

Update Firmware Sub-menu

Updating the device firmware.

Selecting DHCP Mode

Configuring DHCP settings for network connection.

Configuring IP Network Address

Setting the device's IP network address manually.

VS-44 DT Factory Default Reset

Resetting to Factory Default Configuration

Resetting device to factory default parameters and rebooting.

Operating the VS-44 DT Remotely via Web Pages

Supported Operating Systems and Browsers

List of compatible operating systems and web browsers.

VS-44 DT Web Interface: Switching Page

Switching Page Overview

Description of the web interface switching page for input selection.

VS-44 DT Web Interface: Device Settings

Device Settings Page Overview

Managing device information and settings via the web interface.

VS-44 DT Web Interface: Firmware and Authentication

Updating Firmware via Web

Procedure for updating device firmware through the web interface.

Authentication Page Overview

Configuring web page authentication and password settings.

VS-44 DT Web Interface: EDID Management

EDID Page Overview

Managing EDID data (copying, reading) via the web interface.

VS-44 DT Web Interface: Routing and Audio

RS-232 Routing Page Overview

Routing RS-232 data to outputs through the web interface.

VS-44 DT Web Interface: Audio Settings

Audio Settings Page Overview

Adjusting audio output volume and mute status via the web interface.

VS-44 DT Web Interface: Switching Timeout

Switching Timeout Page Overview

Configuring switching timeouts for signal loss or cable unplug events.

VS-44 DT Web Interface: About Page

About Page Overview

Displays device firmware revision and company details.

Updating the VS-44 DT Firmware

Main Microcontroller Firmware Upgrade

Procedure to upgrade the main microcontroller firmware.

IO Microcontroller Firmware Upgrade

Procedure to upgrade the I/O microcontroller firmware.

VS-44 DT Technical Specifications

Default IP Parameters

Default RS-232 and Ethernet IP parameters for the VS-44DT.

VS-44 DT Protocol 3000 Commands

Understanding Protocol 3000

Explanation of Protocol 3000 command structure and syntax.

Kramer Protocol 3000 Syntax

Syntax and delimiters used in Kramer Protocol 3000 commands.

Protocol 3000 Commands Overview

Categorized list of available Protocol 3000 commands.

VS-44 DT System Commands (Protocol 3000)

System Commands Reference

Detailed reference for system-related Protocol 3000 commands.

VS-44 DT Protocol 3000: Build Date & Factory Reset Commands

BUILD-DATE Command

Command to retrieve the device's build date.

FACTORY Command

Command to reset the device to factory default configuration.

VS-44 DT Protocol 3000: Help & Model Commands

HELP Command

Command to get command list or help for specific commands.

MODEL Command

Command to retrieve the device model information.

VS-44 DT Protocol 3000: Protocol Version & Reset Commands

PROT-VER Command

Command to get the device's protocol version.

RESET Command

Command to reset the device.

VERSION Command

Command to retrieve the firmware version number.

VS-44 DT Protocol 3000: Timeout & Display Commands

AV-SW-TIMEOUT Command

Command to set auto switching timeout parameters.

DISPLAY Command

Command to get output HPD status.

VS-44 DT Protocol 3000: Signal & Preset Recall Commands

SIGNAL Command

Command to get input signal status.

PRST-RCL Command

Command to recall saved preset configurations.

VS-44 DT Protocol 3000: Preset Store & Lock Commands

PRST-STO Command

Command to store current configurations into presets.

LOCK-FP Command

Command to lock or unlock front panel buttons.

VS-44 DT Protocol 3000: Machine Number & Video Commands

MACH-NUM Command

Command to set the device's machine number.

Video Commands Reference

Overview of commands for video control.

VMUTE Command (Video)

Command to set or get video mute status on outputs.

VS-44 DT Protocol 3000: EDID Handling Commands

EDID Handling Commands Overview

Overview of commands for managing EDID data.

CPEDID Command

Command to copy EDID data from output to input EEPROM.

VS-44 DT Protocol 3000: Audio Commands

Audio Commands Overview

Overview of commands for controlling audio mute and volume.

MUTE Command (Audio)

Command to set or get audio mute status.

VOLUME Command (Audio)

Command to set or get simple audio volume.

VS-44 DT Protocol 3000: Switching Commands

Switching Commands Overview

Overview of commands for switching inputs/outputs and routing.

VID Command (Switching)

Command to set or get video switch state.

ROUTE Command (Switching)

Command to set or get layer routing.

VS-44 DT Protocol 3000: Communication Commands

Communication Commands Overview

Overview of commands for network communication settings.

ETH-PORT Command

Command to set or get Ethernet port protocol.

VS-44 DT Protocol 3000: DHCP and Gateway Commands

NET-DHCP Command

Command to set or get DHCP mode.

NET-GATE Command

Command to set or get the gateway IP address.

VS-44 DT Protocol 3000: IP and MAC Address Commands

NET-IP Command

Command to set or get the IP address.

NET-MAC Command

Command to get the MAC address.

VS-44 DT Protocol 3000: Subnet Mask Command

NET-MASK Command

Command to set the subnet mask.

Related product manuals