VS-44DT - Technical Specifications
43
43
10.1 Default IP Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Route the video from the HDMI IN 3 to Out1):
#VID 3>1<cr>
Ethernet
IP Address:
192.168.1.39
Subnet Mask:
255.255.0.0
Default Gateway:
192.168.0.1
TCP Port #:
5000
Default UDP Port #:
50000
Maximum TCP Ports:
4
Maximum UDP Ports:
10
Full Factory Reset
Menu:
Menu-> RESET TO DEFAULT-> Change the option to YES
and press Enter (to complete the reset process you need to
turn the power off and then on again).
Web Page:
Go to the Device Settings page and click FACTORY RESET
Protocol 3000:
#factory<cr> command