VS-44DT - Operating the VS-44DT
6.5 Resetting the Device to Factory Default Configuration
The VS-44DT can be reset to factory default configuration either by sending a
Protocol 3000 command or by using the front panel buttons.
To reset the device to the factory default configuration by sending a P3000
command:
1. Connect to the VS-44DT from a PC via the serial port using the following
parameters:
115200, 8, 1, none
2. Send the P3000 command to reset the device to factory default (see
Section 11.4.1.3).
After a few seconds the VS-44DT is reset to factory default.
To reset the device to the factory default configuration using the front panel
buttons:
1. Press the Menu button.
The Menu button lights and the first option on the menu appears.
2. Use the up (▲) and down (▼) arrows on the keypad to scroll to the RESET
TO DEFAULT option.
3. Press the Enter button.
The Reset to Default No and Yes options appear.
4. Use the left (◄) and right (►) arrows on the keypad to select Yes.
5. Press Enter.
After a few seconds the standby readout is displayed and the device is reset
to factory default.