11.4.1.11 SIGNAL
Functions
Permission
Transparency
Set:
-
-
-
Get
SIGNAL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get input signal status
#SIGNAL?SPinp_idCR
Response
~nn@SIGNALSPinp_id,statusCR LF
Parameters
inp_id input number: IN 1=1, IN 2=2, IN 3=3, IN 4=4
status signal status according to signal validation: 0 (Off), 1 (On)
Response Triggers
After execution, a response is sent to the com port from which the Get was received
A response is sent after every change in input signal status from On to Off or from Off to On
K-Config Example
Get the input signal status of HDMI In:
“#SIGNAL? 1”,0x0D
11.4.1.12 PRST-RCL
Functions
Permission
Transparency
Set:
PRST-RCL
End User
Public
Get
-
-
-
Description
Syntax
Set:
Recall saved preset list
#PRST-RCLSPpresetCR
Get:
-
-
Response
~nn@PRST-RCLSPpresetCR LF
Parameters
preset input number: IN 1=1, IN 2=2, IN 3=3, IN 4=4
K-Config Example
Recall preset 1:
“#PRST-RCL 1”,0x0D