EasyManuals Logo

Kranzle 1132 User Manual

Kranzle 1132
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Electrical connection
The machine is supplied with an electrical power cable with plug. The mains plug must
be fitted to a standard grounded socket with a 30mA residual current operated device.
The socket must be protected with a 16A delay action fuse on the mains side.
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a minimum
cross section of 1.5 mm².
Plug connections must be of a spray-proof design, and may not be located on a wet
floor. With extension cables of more than 10 m the minimum cross section must be
2.5 mm! When using a cable drum, always keep the cable wound as far as possible.
Insufficient quantity of electricity
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline.
Consequently the motor of the high-pres-
sure cleaner does not start or even blows.
The power supply may also be insufficient
if the power cable is too long or too thin.
If extension cables are too long, this may
lead to a voltage drop causing
malfunctions or start-up difficulties.
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
11
Kränzle 1132: 230 V ~, 12,0 A, 50 Hz

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kranzle 1132 and is the answer not in the manual?

Kranzle 1132 Specifications

General IconGeneral
BrandKranzle
Model1132
CategoryPressure Washer
LanguageEnglish

Related product manuals