Inspections
The machine must be inspected according to the “Guidelines for Liquid
Spray Devices” at least once every 12 months by a qualified person, to
ensure that continued safe operation is guarateed. The results of the inspec-
tion are to be recorded in writing. This may be done in any form.
Accident prevention
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and
the high pressure water jet. The “Guidelines for Liquid Spray Devices” must
be complied with. (see page 14 and 15)
Check the oil level at the oil sight glass prior to each use.
(Ensure horizontal position!)
Oil change:
The oil of your high pressure pump should be changed after approx. 40
hours of operation, or no later than when it takes on a grey or whitish colour.
To change the oil, remove the two combination screws on the base-plate at
the bottom, take off the base-plate and pull out the oil drainage hose. Put
the hose over a container and take off the closure cap. Put the pump into
horizontal position to drain off the oil. The oil must be caught in a container
and disposed of in a responsible, legal manner.
New oil: 0.3 l - Motor oil: W 15/40
Guarantee
The guarantee period is 24 months according to VDMA.
The guarantee is void if changes are made to the safety devices or if the
machine is used at excess temperatures or speeds. The guarantee is also
void if the machine is used with a voltage below the required rating, with less
than the required amount of water, with dirty water and external damage to
the pressure gauge, nozzle, high pressure hose and spray device.
This guarantee is not applicable for spare parts.
Our operating instructions must be complied with.