37
The machine must be inspected according to the “Guidelines for Liquid Spray
Devices” at least once every 12 months by a qualified person, to ensure that
continued safe operation is guarateed. The results of the inspection are to be
recorded in writing. This may be done in any form.
Inspections
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The “Guidelines for Liquid Spray Devices” must be com-
plied with. (see page 14 and 15)
Accident prevention
Check the oil level at the oil sight glass prior to each use.
(Ensure horizontal position!)
Oil change:
The oil of your high pressure pump should be changed after approx. 40 hours of
operation, or no later than when it takes on a grey or whitish colour. To change the
oil, remove the two combination screws on the base-plate at the bottom, take off
the base-plate and pull out the oil drainage hose. Put the hose over a container and
take off the closure cap. Put the pump into horizontal position to drain off the oil.
The oil must be caught in a container and disposed of in a responsible, legal
manner.
New oil: 0.3 l - Motor oil: W 15/40
General rules
Warranty
This warranty covers material and/or workmanship related defects only and does not
extend to ordinary wear.
Machine must be operated according to enclosed operating instructions which are part of
present warranty conditions.
ll products sold directly to private customers are warrantied for a period of 24 months,
whereas the warranty period for industrial purchases is limited to 12 months.
In case of any warranty claims, please have your HP cleaner together with accessories
and your purchase document ready and contact your nearest dealer or authorized service
point which can also be looked up in the internet at www.kraenzle.com
.
Warranty is void in case of attempts to modify any of the safety devices or in the event of
exceeding temperature or rpm limits - this also applies to undervoltage, low water and/or
polluted water. Gauge, nozzle, valves, sealing gaskets, high pressure hose and spray
equipment are considered wear parts and do not fall under this warranty.